Event/Reading
Sensor Name
type code
Health Status
7Fh
Bx: Health Status
(OEM Health Status)
Sensor Type
Sensor Specific offset
24h
00h Status not available in current state
(Platform Alert)
01h Healthy
02h Informational fault
03h Minor fault
04h Major fault
05h Critical fault
Event Trigger
Event Data 3:
If the sensor is an aggregation sensor, then event data 2 is used to
return the ID of the first sensor from the aggregation that caused the
fault.
Sensor Aggregation List:
FRU0
ID:
Sensor Name
04h:
Temp Brd Inlet
05h:
Temp Brd Outlet
07h:
Temp BMC
08h:
Temp CPU 1
09h:
Temp CPU 2
0Eh:
Vcc +12.0V SUS
0Fh:
Vcc +3.3V SUS
10h:
Vcc +1.5V SUS
11h:
Vcc +1.2V SUS
FRU1/2:
ID:
Sensor Name
04h:
Bx:IPMI Watchdog
06h:
Bx:Vddq
07h:
Bx:Vcc +3.3V
08h:
Bx:Vcc +3.3V L
09h:
Bx:Vcc +1.5V
0Ah:
Bx:Vcc +1.05V
0Eh:
Bx:PWROK Capt. 1
0Fh:
Bx:PWROK Capt. 2