ID
Hex ID
Sensor Name
24
0x18
IPMI Info-1
25
0x19
IPMI Info-2
26
0x1A
POST Value
27
0x1B
Health Status
28
0x1C
EventRcv ComLost
29
0x1D
BMC Reboot
30
0x1E
BMC Storage Err
31
0x1F
BMC SEL State
32
0x20
SEL Time Set
33
0x21
Jumper Status
34
0x22
Thermal Error
Sensor Type Code
Reading Type Code
70h (OEM Kontron Internal
C0h (OEM Firmware Info)
Diagnostic)
71h (OEM Kontron Internal
C0h (OEM Firmware Info)
Diagnostic)
C6h (OEM POST Value)
6Fh (Sensor Specific)
7Fh
24h (Platform Alert)
(OEM Health Status)
1Bh Cable/Interconnect
03h (Digital Discrete)
24h (Platform Alert)
03h (Digital Discrete)
28h (Management
6Fh (Sensor Specific)
Subsystem Health)
10h (Event Logging Disable)
6Fh (Sensor Specific)
12h (System)
6Fh (Sensor Specific)
D3h (OEM Jumper Status)
6Fh (Sensor Specific)
0Ah (Cooling Device)
03h (Digital Discrete)
www.kontron.com
MSP8020 Series User Guide Rev. 1.1
Description
Internal Management Controller
firmware diagnostic
Internal Management Controller
firmware diagnostic
Show current postcode value
(No event generated)
General health status
(Aggregation of critical sensors)
Communication loss with the event receiver (ShMC)
BMC Reboot detection
Management sub-system health
(non volatile memory error)
Specify the status of the SEL
(Cleared/Almost full/Full)
Specify when SEL time change
Reflects on-board jumper presence
Cooling problem