Power Fist 8843773 Instructions Manual page 12

5/16 in.straight grip air punch and flange tool
Table of Contents

Advertisement

Available languages

Available languages

8843773
Problem(s)
Tool runs
slowly. Air flows
slightly from
exhaust.
Tools will not
run. Air flows
freely from
exhaust.
Tool will not
shut off.
Loss of power
or erratic
performance.
12
5/16 in. Straight Grip Air Punch and Flange Tool
Possible Cause(s)
1. Air regulator in closed
position.
2. Damage or excessive
wearing of internal
parts.
3. No oil in tool.
4. Low air pressure.
Damage or excessive
wearing of internal parts.
1. Throttle valve o-ring
dislodged from inlet
valve seat.
2. Trigger mechanism
jammed or dirty.
1. Excessive drain on the
air hose. Incorrect
size or type of hose
connectors.
2. Moisture or restriction
in the air hose/tank
3. Air compressor has
insufficient flow.
Suggested Solution(s)
1.
Open the air regulator to
desired airflow.
2a. Have a qualified technician
service the tool.
2b. Replace tool or parts.
3.
Lubricate the tool.
4a. Adjust the regulator on the tool
to the maximum setting.
4b. Adjust the compressor regulator
to a maximum of 90 PSI / 6.3
BAR.
1.
Have a qualified technician
service the tool.
2.
Replace tool or parts.
1.
Replace throttle valve
o-rings.
2.
Clean trigger mechanism and
lubricate.
1a. Check the air hose and confirm
the hose fitting is correct for
the inlet bushing.
1b Do not use multiple hoses
connected together with quick-
connect fittings. Connect the
hoses together.
2.
Depressurize system and drain
tank and air hose of water. Oil
and run until no water is
evident. Oil tool again and run
for 1-2 sec.
3.
Ensure tool is connected to a
compressor with a rate flow
that matches the tool.
For technical questions call 1-800-665-8685
V1.0

Advertisement

Table of Contents
loading