Brainboxes CC-310 Hardware Manual

Brainboxes CC-310 Hardware Manual

Brainboxes cc-310 pci cards: user guide
Hide thumbs Also See for CC-310:
Table of Contents

Advertisement

Quick Links

Hardware Manual
1.12 EDITION MARCH 1998

Advertisement

Table of Contents
loading

Summary of Contents for Brainboxes CC-310

  • Page 1 Hardware Manual 1.12 EDITION MARCH 1998...
  • Page 2 Guarantee. FULL 36 MONTHS GUARANTEE. We guarantee your Serial Port Card for a full 36 months from purchase, parts and labour, provided it has been used in the specified manner. In the unlikely event of failure return your interface to your Dealer, with proof of purchase, who will determine whether to repair or replace this product with an equivalent unit.
  • Page 3 PCI VELOCITY / OPTO ISO RS422/485 PCI OPTO ISOLATED RS422/485 AUTOGATING PCI VELOCITY RS422/485 AUTOGATING These products conform to the following standards: CE standard: EN55022:1987 Class B IEC 801-2: IEC 801-3: IEC 801-4: PCB: IEC 249-2-5 NEMA L1 1-10 DIN 40802 UTE C 93-711 BS 4584 MIL P-13949E...
  • Page 4 Introduction PCI VELOCITY / OPTO ISO RS422/485 PCI VELOCITY RS422/485 AUTOGATING PCI OPTO ISOLATED RS422/485 AUTOGATING OUTLINE CONTENTS Chapter 1 - Supplied Serial Solution Software. Chapter 2 - PCI Velocity RS422/485 Specifications. Chapter 3 - PCI Dual RS422/485 Software Configuration Guide. Chapter 4 - Additional RS422/RS485 Information.
  • Page 5: Table Of Contents

    PCI VELOCITY / OPTO ISO RS422/485 Table of Contents 1 ... 1 HAPTER ..1 NTRODUCTION Introducing Serial Solution Software..1 Serial Solutions For DOS..1 Serial Solutions For Windows 3.x... 3 Serial Solutions For Windows 95... 4 Serial Solutions For Windows NT.
  • Page 6 Introduction Advanced Port Settings..26 Uninstalling Serial Solutions PCI..28 ONFIGURING ORTS Determining PCI RS422/485 Resources..29 Windows 3.x Software Installation..30 Serial Port Installation..31 Configuring The COM Ports..33 Deleting Ports in Windows..34 Restarting Windows.
  • Page 7: Chapter 1

    PCI VELOCITY / OPTO ISO RS422/485 SOLUTIONS SOFTWARE. Introduction. This chapter is a brief description of the Serial Solutions software package; this can also be purchased SEPARATELY and is available from YOUR DEALER. Introducing Serial Solution Software. The perfect partner for any Serial Port is Serial Solutions Software! Serial Solutions is a fully featured suite of programs designed to squeeze the most from PC serial communications.
  • Page 8 Serial Solutions programs: - NewCOM.sys A device driver, it supports COM1 to COM16, allowing 16 serial ports to be used under DOS. It also includes an interrupt handler for enhanced performance with user definable buffer languages, it is the heart of the Serial Solution. implementing using any combination of the DTR, DSR, CTS, RTS, and DCD lines, and a software handshake...
  • Page 9: Serial Solutions For Windows 3.X

    PCI VELOCITY / OPTO ISO RS422/485 file I/O to ports. They contain many lines of code and are thus harder to grasp. They demonstrate in depth serial port programming in a variety of languages but they are also useful tools for using serial devices. Comtest.exe Comtest is a short but invaluable program that is used to check that the serial port at a particular I/O...
  • Page 10: Serial Solutions For Windows 95

    Serial Solutions Serial Solutions For Windows 95. Windows 95 has an improved communication API and directly supports up to 255 ports. Our Windows 95 driver supports the shared interrupt mechanism used on our multiport cards. Serial Solutions for Windows 95 consists of the following programs: - SSCards.inf The information file to aid the installation process "Have Disk...”...
  • Page 11 PCI VELOCITY / OPTO ISO RS422/485 Serial Solutions over 150 pages of in-depth technical detail with comprehensive indexes and table of contents. We guarantee your Serial Solution Software package for a full 12 months from purchase. A complete technical backup service is available to ensure that you get the maximum performance out of your investment.
  • Page 12: Chapter 2

    Specifications PCI VELOCITY RS422/485 & PCI OPTO ISOLATED RS422/485 SPECIFICATIONS Introduction. This chapter details the specifications of the PCI Velocity RS422/485 card and PCI Opto Isolated RS422/485 and explains how to configure the RS485 Multiplex jumpers present on both cards. These half-sized cards will work happily in any PCI 2.0 or greater compliant PC compatible.
  • Page 13: General Pci Rs422/485 Serial Port Features (Cont)

    PCI VELOCITY / OPTO ISO RS422/485 Autogating low level RS485 half duplex (2 wire) control General PCI RS422/485 Serial Port Features (cont). Clock Input: Drivers: High Level Voltage: Low Level Voltage: High Level Current: Low Level Current: Receivers: Difftial I/P threshold: 200mV max. Hysteresis: Input Impedance: Autogating.
  • Page 14: Optical Isolation

    Specifications system. To all intents and purposes, it looks just like an ordinary RS232 COM port to the host PC. Autogating for half duplex operation is a necessity for Windows 95, NT and the forthcoming Windows 98 (Memphis) and Windows NT 5. Optical Isolation.
  • Page 15 PCI VELOCITY / OPTO ISO RS422/485 Figure 2-1. PCI VELOCITY RS422/485 Card Layout. TX/RX1+ TX/RX1- TX/RX2- TX/RX2+ RS485 Multiplex jumper block PCI VELOCITY RS422/485 Specifications: Dimensions: I/O Connection: Weight: 5 x 3 in, 120 x 85 mm Serial Port 1: 9 pin Male D type. Serial Port 2: 9 pin Male D type.
  • Page 16 Specifications Figure 2-2. PCI Opto Iso RS422/485 Card Layout. TX/RX1+ TX/RX1- TX/RX2- TX/RX2+ RS485 Multiplex jumper block PCI Opto Iso RS422/485 Specifications: Dimensions: I/O Connection: Weight: Optical Isolation PCI VELOCITY / OPTO ISO RS422/485 5 x 3 in, 126 x 99 mm Serial Port 1: 9 pin Male D type.
  • Page 17: Configuring The Pci Rs422/485 Cards

    Figure 2-3. 9 Pin D Connector Port Pinouts. Configuring The PCI RS422/485 Cards. PCI cards require no hardware configuration for IRQ and address allocation - this is done automatically at start up by the PC. However, the PC Velocity RS422/485 and PCI Opto Iso RS422/45 both have two sets of jumpers for configuration of RS485 multiplex modes, how to configure these jumpers is shown below.
  • Page 18 Specifications Port 1 With Full Duplex Settings. Both jumpers left unconnected (not shorted). Port 1 With Half Duplex Settings. Both jumpers shorted, causing the RXD- & TXD- and the RXD+ & TXD+ signals to short together at the 9-pin connector. The multiplex jumpers should only be set for RS485 Half Duplex operation, when one twisted pair is used to interconnect both transmit and receive lines.
  • Page 19: Hardware Installation

    PCI VELOCITY / OPTO ISO RS422/485 Hardware Installation. STEP 1: Before the PC card can be installed the power to the PC MUST be switched OFF, and to ensure extra safety, the power lead removed from the PC. STEP 2: Remove the PC case. Step 3 - Removing Blanking Cover Step 4 - Inserting The PCI Serial Card.
  • Page 20: Problems

    Specifications STEP 6: Now replace the system unit’s cover by carefully sliding it down and back over the system unit. Replace the cover mounting screws. STEP 7: After attaching all the monitor and keyboard cables, power up the PC. Do not forget the mains power cable! The PC should then power on in the normal way.
  • Page 21: Chapter 3

    PCI VELOCITY / OPTO ISO RS422/485 PCI VELOCITY RS422/485 & PCI OPTO ISOLATED RS422/485 SOFTWARE CONFIGURATION Introduction. This section contains the installation procedures of the PCI VELOCITY RS422/485 card, with the Windows 95 & 98, Windows NT DOS, and Windows 3.x operating systems. As previously noted, the install procedure for the Velocity and Opto Isolated PCI RS422/485 cards are the same, with the only difference being the reported card name in Windows 95 &...
  • Page 22 Software Configuration Windows will then display the "Update Device Driver Wizard", which asks you to “insert any disk which came with the PCI card”. Insert the Windows 95 installation disk into an appropriate drive and click 'Next'. The Wizard should then display the following: Click Finish.
  • Page 23 PCI VELOCITY / OPTO ISO RS422/485 After copying the file, Windows 95 will then detect each of the serial ports in turn and install them as communications ports. When the "Device Manager" is viewed the PCI R422/485 card will appear under the "Multi-function adapters" branch as either PCI Velocity RS422/485 card or PCI Opto Iso RS422/485 (parent device).
  • Page 24: Pci Velocity Rs422/485 Card Settings In Windows 95

    Software Configuration PCI Velocity RS422/485 Card Settings In Windows 95 & 98. Select the PCI Velocity RS422/485 card from the "Multi- Function Adapter" entry in Device Manager serial and click on properties to view the cards general properties; clicking on the Serial Solutions tab produces: In this window, the COM port assignment may be changed, simply by selecting a new COM port value from the pull down...
  • Page 25: Pci Rs422/485 Port Settings In Windows 95 & 98

    PCI VELOCITY / OPTO ISO RS422/485 All COM ports present will be listed under the entry "Ports (COM & LPT)." The above screenshots indicates that COM2 - 4 and COM7 and above are not installed, and therefore may be used. PCI RS422/485 Port Settings In Windows 95 &...
  • Page 26 Software Configuration the ranges of baud rate values available at the Maximum Baud Rate Settings. Table 3-1 Maximum Baud Rate Settings. 115200 1200 1800 2000 Selectable Baud 2400 Rates 3600 4800 7200 9600 19200 38400 57600 115200 Note: Many serial comms applications will not actually register the ports as running at baud rates of above 115200.
  • Page 27 PCI VELOCITY / OPTO ISO RS422/485 Flow Control: Maximum Baud Rate Setting: Clicking on the Serial Solutions tab will display: Settings available in this window are: 1. FIFO Settings. Enable FIFO - turns the selected ports FIFO buffer on or off. It is strongly recommended that the FIFO for both ports is left enabled.
  • Page 28 Software Configuration slower machine. Selecting a high value will send more data-bytes per interrupt, and will give more time for multi-tasking operations. 2. Automatic Hardware Flow Control. One of two options may be selected: Off (Default) - This will turn off automatic flow control.
  • Page 29: Configuring Ports I N Microsoft Windows Nt 4.0

    PCI VELOCITY / OPTO ISO RS422/485 Configuring Ports In Microsoft Windows NT 4.0. Microsoft Windows NT Provides built in support for 255 standard serial ports. To setup your PCI RS422/485 serial card you should follow these steps. Please note that to change any kind of hardware configuration under Windows NT you must be logged in as a user with Administrator level privileges, if you do not have these please contact your system administrator.
  • Page 30: Examining Card Configuration

    Software Configuration Examining Card Configuration. Go to Control Panel (Start/Settings/Control Panel) and double click on Serial Solutions PCI: You will be presented with a Serial Solutions PCI Port Configuration window: Chapter 3 Page 24 PCI VELOCITY / OPTO ISO RS422/485 Opto Iso users, these entries under card will appear as:...
  • Page 31: Configuring Ports

    PCI VELOCITY / OPTO ISO RS422/485 Configuring Ports. To view the settings of a port, select it and click on settings, and then click on the resources tab: Settings available in this window are: Settings available in this window are: 1.
  • Page 32: Advanced Port Settings

    Software Configuration 6. Advanced - see the section below, titled "Advanced Port Settings." 7. Restore Defaults - when clicked, resets the selected COM port to the following values: Baud Rate: Data Bits: Parity: Stop Bits: Flow Control: Advanced Port Settings. When the Advanced button of Port Settings is selected the following dialogue is displayed: Settings available in this window are:...
  • Page 33 PCI VELOCITY / OPTO ISO RS422/485 buffer on or off. It is strongly recommended that the FIFO for both ports is left enabled. Receive Buffer - These settings allow the selection of a receiver FIFO trigger setting. Selecting a low value will allow the interrupt to be serviced quicker, which is good for slow machines.
  • Page 34: Uninstalling Serial Solutions Pci

    Software Configuration Settings" in Chapter 2, to ensure accurate and error free data transmission. Force CTS True, determines whether the CTS handshake signal is INPUT from the external serial device or is permanently forced true on the card. The serial ports own RTS OUTPUT handshake signals are always taken out to the serial port connector.
  • Page 35: Configuring Ports I N Windows 3. X

    PCI VELOCITY / OPTO ISO RS422/485 Configuring Ports In Windows 3.x The Windows 3.x installation procedure consists of two steps after the PCI RS422/485 card is inserted: 1. Determining the resources that the PCI RS422/485 card has claimed. 2. Informing Windows 3.x of those resources. Determining PCI RS422/485 Resources.
  • Page 36: Windows 3.X Software Installation

    Software Configuration Windows 3.x Software Installation. Place the supplied Serial Solutions for Windows 3.x disk in a suitable drive. From File Manager choose ‘Run’ and enter a:\setup (where a: is the path to the floppy drive with the installation disk). Click OK, the Setup Program Main Screen is displayed: By default, all component options will be installed, selecting the "Del All"...
  • Page 37: Serial Port Installation

    PCI VELOCITY / OPTO ISO RS422/485 When you have made your choice of Component Options click Continue and when the setup program has finished select the Done button. Note: If the Serial Port driver options has been selected, after the setup program has finished, Windows will display a restart message - answer Yes and Serial Solutions will be ready to run upon Windows restarting.
  • Page 38 Software Configuration The following dialogue will be displayed: To add a COM port: Click on the add button and a Window similar to the following will be displayed: In Standard Settings: In the COM Base field, enter the value 0140. Note: COM ports are defined with an i/o address range, which in this case, begins at 0140 and all subsequent ports have an i/o address that is 8 higher than the...
  • Page 39: Configuring The Com Ports

    PCI VELOCITY / OPTO ISO RS422/485 Note: The values used in the above section were those returned by the BBCARDS program, as described in the above section. When you have finished, click on OK. A restart message will be displayed; to save time only restart when both ports have been added and correctly configured.
  • Page 40: Deleting Ports In Windows

    Software Configuration Note: A port that has been added has the default values of: Baud Rate: Data Bits: Parity: top Bits: Flow: Change the communications Settings in the COM Ports to match the baud rate, parity settings etc. of the remote serial device. Deleting Ports in Windows.
  • Page 41: Configuring Ports I Ndos

    PCI VELOCITY / OPTO ISO RS422/485 Configuring Ports In DOS. The DOS installation procedure consists of two steps after the PCI RS422/485 card is inserted: 1. Determining the resources that the PCI RS422/485 has claimed. 2. Informing the Serial Solutions DOS device driver of those resources.
  • Page 42: Newcom.sys Parameters

    Software Configuration NEWCOM.SYS Parameters. The NewCOM.SYS device driver included with the PCI RS422/485 driver software is used to set up the card in DOS and has the following syntax: NEWCOM.SYS /A port address, /I IRQ,range /B number buffer /S buffer /H hardware handshake Where /A port address specifies COM port number followed by a hexadecimal address in the form /Ax,y where x is COM port range and y is I/O address.
  • Page 43 PCI VELOCITY / OPTO ISO RS422/485 receive its sets DTR output true. The DSR and DCD inputs are ignored. The RTS output line is set true just in case the external serial device needs a true signal. Type 1 RS422 RTS/CTS - The PC only transmits when CTS is input true.
  • Page 44: Configuring And Installing Newcom.sys

    Software Configuration Note: If hardware handshaking is not specified in the NEWCOM.SYS parameters, type 4, 3 Wire Handshake is selected automatically. Configuring And Installing NEWCOM.SYS To load the Serial Solutions for DOS device driver an entry needs to be added to the CONFIG.SYS file. Any simple text editor, EDIT for example, can edit the CONFIG.SYS file for example.
  • Page 45: Modifying Command Line Parameters

    PCI VELOCITY / OPTO ISO RS422/485 COM port values of 5 to 6, all preceding COM ports, must have buffers assigned to them also. Buffer Size. /S512 Buffer size set to 512 bytes. Hardware Handshaking. /H,4 Type 4, 3 Wire Handshake selected for all ports. Type 4, 3 Wire Handshake selected for all ports.
  • Page 46: Chapter 4

    RS422/485 Information ADDITIONAL RS422/485 OPERATION The RS422 Standard. The RS422 standard defines a serial communications standard. RS422 is a high speed and/or long distance data transmission. Each signal is carried by a pair of wires and is thus a differential data transmission system. Over distances up to 40 feet the maximum data rate is 10 Megabits per second, and for distances up to 4000 feet the maximum data rate is 100 Kilobytes per second.
  • Page 47: Terminating Impedance's

    PCI VELOCITY / OPTO ISO RS422/485 resistor should be used to terminate either end of the main line. If more than one device may transmit data, the RTS line is used as transmit enable signal, so preventing contention between talkers. Up to 32 Driver/Receiver Pairs Line Length 40 Feet =...
  • Page 48: Fail Safe Open Circuit Detection

    RS422/485 Information Fail Safe Open Circuit Detection Open circuit is when there are no drivers on the circuit. This occurs by design in party line multi driver/receiver systems and unintentionally when the twisted pair line is accidentally cut or disconnected or the transmitting device fails. In RS485 party line systems there are extended periods of time when none of the many possible talkers are gated onto the bus.
  • Page 49: Rs422 Serial Port Cables

    PCI VELOCITY / OPTO ISO RS422/485 handshake inwards. There is no need to carry the ground from one device to another. This RS422 arrangement allows data to be transmitted and received simultaneously since each signal has its own data cable pair.
  • Page 50: Rs485 Operation

    RS422/485 Information Note: i.) Receiver ends terminated in characteristic impedance ONBOARD resistor networks. ii.) USE BELDEN TYPE 9729 etc. see above. iii.) RS485 Gating & Multiplex Jumpers as Factory Set. RS485 Operation. The RS485 standard is intended for up to 32 driver receiver pairs on the bus.
  • Page 51: Rs485 Cable

    PCI VELOCITY / OPTO ISO RS422/485 RS485 Cable. For best noise immunity use twisted pair cables to make the RS485 connection. In Half Duplex wiring only 1 twisted cable pair is needed. Two twisted pair cables are needed for Full Duplex communications.
  • Page 52: Rs485 Many Talkers- Many Listeners, Half Duplex

    RS422/485 Information off the main not terminated. In the above scheme, one RS485 device is talk only, it transmits data, but it does not receive any. The other RS485 devices are receive only, they do not transmit any data at all. Figure 4-3 gives the RS485 Gating jumper settings.
  • Page 53: Rs485 Many Talkers- Many Listeners, Full Duplex

    PCI VELOCITY / OPTO ISO RS422/485 receive. The twisted pair ends are wired to both RXD+ & TXD+ and RXD- & TXD- at each RS485 device! RS485 Many Talkers- Many Listeners, Full Duplex. The RS485 many talkers, many listeners, Full Duplex system can be used when all the RS485 devices have separate Transmit and Receive channels.
  • Page 54 RS422/485 Information PCI VELOCITY / OPTO ISO RS422/485 at any one time. Each RS485 device recognizes commands and data addressed to it, it only talks when the PC commands it to do so. When the RS485 device receives the command to talk from the PC, it gates its TXD drivers on, sends the data down the device TXD channel, and disables its TXD drivers.
  • Page 55: Optional Grounding Arrangements

    PCI VELOCITY / OPTO ISO RS422/485 Optional Grounding Arrangements. Proper operation of the cable circuit, according to TIA EIA: 485 A (1995) requires that the cable ground shield is not connected directly to the equipment ground shield. A current limiting resistor should be used in series with the shield to avoid possible large current flow due to differences in ground potential.
  • Page 56 RS422/485 Information Configuration A) connected to protective ground, at one point only by a 100 resistor with a power dissipation rating of 1/2W. An additional provision may be made for the resistor to be bypassed with a strap to connect signal common and protective ground directly together when specific installation conditions necessitate.
  • Page 58: Index

    Index PCI VELOCITY / OPTO ISO RS422/485 Index 1 Megabaud ... 5 115200 Baud... 19 16450 / 16550 ... 1, 5 460800 Baud... 19 921600 Baud... 19 asynchronous ... 5 Autogating ... 5, 6 baud / baud rate... 2, 3 BBCARDS.EXE ...28, 34, 37 Belden ...
  • Page 59 PCI VELOCITY / OPTO ISO RS422/485 Index jumper ...10, 43, 44-47 last... 45 loop back ... 3 Maximum Baud Rate ... 18, 19 Megabaud ...See 921600 baud mode... 2, 47 open circuit ... 41 Optical Isolation... 5, 7, 9, 16, 28, 34 parent device...
  • Page 60 This Page IntentionallyBlank...
  • Page 61 ALSO AVAILABLE FROM YOUR SUPPLIER VELOCITY SERIAL RANGE 1 Megabaud serial comms AT VELOCITY RS232 VELOCITY RS422/485 PCI SERIAL RANGE PCI RS232 2 PORT PCI RS232 4 PORT PCI RS232 8 PORT PCI VELOCITY RS422/485 PCI VELOCITY RS232 PCI OPTO DUAL RS422/485 STANDARD SERIAL RANGE AT TWIN 9 RS232 AT 1 PORT RS232...

Table of Contents