Programmable DC Power Supply 62000P Series Operating & Programming Manual
3.3.5.5 OTP
The OTP protection will activate when the internal temperature reaches the high limit and the
output will be turned off that is OUTPUT = OFF for protection.
When OTP occurs the main page will prompt a protection message as shown below:
V _ S E T = 8 0 . 0 0 V
0 0 . 0 0 V
O T P
NOTICE
1.
User is unable to change the OTP setting.
2.
The output will turn off when OTP occurs and won't be on again that is OUTPUT = ON
until the internal temperature drops to a certain set value.
3.3.5.6 AC FAULT
The AC FAULT protection will activate when the internal input voltage is not within the
specified range (90~250Vac). The output will turn off that is OUTPUT = OFF for
protection.
When AC FAULT occurs the main page will prompt a protection message as shown below:
V _ S E T = 8 0 . 0 0 V
0 0 . 0 0 V
3-42
I _ S E T = 1 5 . 0 0 A
Figure 3-67
I _ S E T = 1 5 . 0 0 A
A C
F A U L T
Figure 3-68
0 0 . 0 0 A
0 0 . 0 0 A
O F F
0 . 0 W
O F F
0 . 0 W