Chroma 62000P Series Operating & Programming Manual page 118

Programmable dc power supply
Table of Contents

Advertisement

Syntax:
*ESE <NRf>
Parameter:
0 to 255
Example:
*ESE 48
Query Syntax:
*ESE?
Return Parameter: <NR1>
Query Example:
*ESE?
*ESR?
Standard Event Status Register
Type:
Device status
Description:
This query reads the Standard Event Status register and clears it.
Query Syntax:
*ESR?
Return Parameter: <NR1>
Query Example:
Return Example:
*IDN?
Identification Query
Type:
System interface
Description:
This query requests the 62000P to identify itself.
Query Syntax:
*IDN?
Return Parameter: <aard>
Query Example:
*IDN?
String
CHROMA
62012P
01.00
2005/07/14
Return Example: CHROMA 62012P-80-60, 01.00,2005/07/14
*OPC
Operation Complete Command
Type:
Device status
Description:
This command causes the interface to set the OPC bit (bit 0) of the
Standard Event Status register when the 62012P Series has completed all
pending operations.
Syntax:
*OPC
Parameter:
None
*OPC?
Operation Complete Query
Type:
Device status
Description:
This query returns an ASCII "1" when all pending operations are
completed.
Query Syntax:
*OPC?
Return Parameter: <NR1>
Query Example:
1
This command enables the CME and EXE events
of the Standard Event Status Event register.
This query returns current setting of Standard
Event Status Enable.
*ESR?
Return status readings of Standard Event Status register.
48
Description
Manufacture
Model name
Firmware version
Date
Remote Operation
5-7

Advertisement

Table of Contents
loading

Table of Contents