Thoroughly read and understand this manual before installation.
Abide by the national wiring rules in your country.
Do not add any other parts or modify the product in the installation.
The installers shall have refrigeration technician qualification certificates and/or suitable electrical trade
qualifications.
Consult with HOUGHTON or the local distributor in the case of unusual applications or installation
conditions that are not specifically covered by this manual.
The RV or caravan roof shall support the air-conditioner's weight (40kg/88 lbs) without distortion.
Minimum thickness of roof is 75mm/3". Maximum thickness of roof is 135mm/5
If the roof's thickness is greater than 135mm/5
from HOUGHTON or the local distributor.
Load bearing of roof
The roof shall be able to bear the weight of the
air-conditioner and shall be level without accumulating
water. It is suggested that the caravan manufacturer
confirms the suitability of the roof for load bearing.
If the installation hole is not preexisting, then consult
your caravan manufacturer for the most suitable way
to cut the installation hole.
The 360×360mm/14
"x 14
3
/
16
up with wood sections that are at least 20mm/ ¾"thick.
This boarding is to ensure that the roof will not crush
from the installation bolts and that air-conditioned air
does not enter the ceiling space.
Installation Guidance
Installation instructions
Installation requirements
" hole shall be boarded
3
/
16
" you can purchase a "Thick roof kit" to suit your unit
5
16
Block
schematic diagram after fixing the blocks
Block
4
".
5
16
Roof
14
/
"X14
/
"
Roof
3
3
16
16
Block
Block