Houghton BELAIRE H2000 Owner's Manual

Houghton BELAIRE H2000 Owner's Manual

Caravan air-conditioner
Hide thumbs Also See for BELAIRE H2000:

Advertisement

OWNERS MANUAL
CARAVAN AIR-CONDITIONER
MODEL
H2000
H2400
A2801
For your safety,please read this manual
carefully before using the product.
M
N
ODEL
UMBER:
S
N
ERIAL
UMBER:
D
P
ATE
URCHASED:

Advertisement

Table of Contents
loading

Summary of Contents for Houghton BELAIRE H2000

  • Page 1 ODEL UMBER: ERIAL UMBER: URCHASED: OWNERS MANUAL CARAVAN AIR-CONDITIONER MODEL H2000 H2400 A2801 For your safety,please read this manual carefully before using the product.
  • Page 2 Safety Notices Dear user, thank you for choosing a HOUGHTON caravan air-conditioner. For your ease of use and safe maintenance we have included the following symbols in this manual: All the contents with this "Warning" logo are about the safety of the user and the air-conditioner.
  • Page 3: Table Of Contents

    Table of Contents ..............................1 Safety Notes ............................ 2 Product Introduction ..............................3 Packing List ........................... 4 Installation Guidance ........................... 10 Quick Start Guide .......................... 11 Remote control operation ..........................16 Product Maintenance ............................17 Specifications ......................18 Exploded Diagram and Parts List ..........................
  • Page 4: Safety Notes

    Safety Notes Make sure the external electric supply socket of the caravan air-conditioner is effectively grounded in accordance with your local regulations. Failure to ground the unit correctly may cause electric shock or fire. The caravan air-conditioner shall be switched on for electric leakage detection after installation.
  • Page 5: Product Introduction

    D. Choosing and using a generator ● HOUGHTON BELAIRE requires a mains quality AC power source for correct operation. If you decide to supply power using a generator then you are strongly recommended to consult with the generator supplier to confirm suitability and sizing of the generator for your application.
  • Page 6: Packing List

    10.Plenum screws ST4.2×19 pan head screws × 4 11.Countersunk head self tapping screws ST4.2 ×16 × 6 Not shown: ● Manual ×1 ● Remote control & bracket ×1 If you note that any items are missing or damaged then please contact Houghton or the local distributor.
  • Page 7: Installation Guidance

    ● The installers shall be equipped with refrigeration technician qualification certificates and/or suitable electrical trade qualifications. ● Consult with HOUGHTON or the local distributor in the case of unusual applications or installation conditions that are not specifically covered by this manual.
  • Page 8 Angle of inclination of the air-conditioner shall not be greater than 5° and the rear of the air-conditioner shall not be higher than the front. For advice on installations outside of these limits please contact HOUGHTON or the local distributor. ● The figure below shows the minimum clearance distance required between the BELAIRE air-conditioner and any obstructions on the roof and the clearance required on the ceiling for the plenum installation.
  • Page 9 Unit: inch 20 13/16" 4 1/2" Plenum position 14 3/16" 22 9/16" 21 1/8" Direction of travel 14 3/16" " Square hole ( × 14 21 15/16" Position of rooftop unit 39 7/16" Installation of roof mount ● Make sure the roof is clean, dry and free from oil or grease. ●...
  • Page 10 Installation of M8 bolts ● Connect M8 bolts, washers and fixing metal plates in order shown. ● Lift the plenum mounting bracket toward the air- conditioner. ● Insert M8 bolts, washers and metal clamping bars into the 4 corner holes of the plenum mounting bracket.
  • Page 11 ● Pull the air duct down until it engages with the Installation of the plenum assembly plenum mounting bracket. The duct connects to the bracket with four catches that will clicks when ● Connect the socket and plug of the display panel secure.
  • Page 12 Adjust the louver ● Adjust direction and angle of louver by moving blade around its axis. The 2 blades move together. Louvers on opposite sides are symmetrical. ● Fix the plenum assembly on the plenum mounting bracket with four ST4.2×19 pan head screws. Louver swing ●Take out the return air filters and fix the plenum to the ceiling with 4 provided countersunk head screws.
  • Page 13: Quick Start Guide

    Quick Start Guide ● Switch on the power to the air-conditioner at the isolation breaker. ● Using the remote control , start the air-conditioner by pressing " " button and then select fan function by pressing the "MODE" button. ● Operate in low FAN, medium FAN and high FAN in turn to check normal operation. ●...
  • Page 14: Remote Control Operation

    Remote control operation Standard remote control Plenum display Touch screen key Temperature Mode display display...
  • Page 15 1. Operation of the remote control Turn on ● Press the on/off key, the unit turns on, the plenum buzzer beeps once and the running mode and temperature will " " be displayed. FAN mode " " " " " "...
  • Page 16 DRY mode mode, Press the down ▼ ● Press the " " " " " " key, select the key to set the temperature 1℃ lower than the MODE room temperature , and the plenum will display " " and the setting temperature. MODE HEAT mode ▲...
  • Page 17 Note When in the AUTO mode, according to the difference between the setting temperature and the environmental temperature , the plenum will display " " (automatic heating), or " " " " (automatic cooling) in the same time. " " Celsius and Fahrenheit degree change "...
  • Page 18 turn off. When "On" and "OFF" are displayed after their simultaneous 10 flashes, and only current clock is displayed, then the setup of timing to turn the unit on and off is done. ● Turn off timing function: Press the "TIMER" key, when it only shows the clock, the timer function is turned off. ●...
  • Page 19: Product Maintenance

    Product Maintenance Filter ● The return air filter is the only component that needs periodic maintenance. ● Check and clean the filter each week when in use to prevent the filter from being blocked by dirt. ● The filter should be washed frequently to ensure effective cooling and heating. ●...
  • Page 20: Specifications

    Specifications H2000C H2000 H2400 A2801 220-240V/50Hz 220-240V/50Hz 220-240V/50Hz 115V/60Hz R407C/450g R407C/470g R407C/450g R410A/430g 2000W 2000W 2400W 9500BTU/H —— —— 2000W 2400W 1370 —— —— 12.6 —— —— 1020 1590 14.6 2900kPa 2900kPa 2900kPa 600PSIG 1840kPa 1840kPa 1840kPa 236PSIG 110l/s 110l/s 110l/s 235 CFM 62+ 6.5 (...
  • Page 21: Exploded Diagram And Parts List

    Exploded Diagram and Parts List...
  • Page 22 Figure No. Name 18-12-13 Mushroom head screw, white, M5 Canopy (silk-screenpattern) 4728-1000-01 1(H2400) Canopy (silk-screenpattern) 4718-1000-01 1(H2000C) Canopy (silk-screenpattern) 4748-1000-01 1(H2000) Canopy (silk-screenpattern) 7388-1000-01 1(A2801) 4728-1210-11 Condenser insulating layer 4708-1000-15 Pipe clamp 4728-1000-08 Evaporator housing 4728-1000-07 External fan motor bracket 4728-1000-13 Outside fan mounting studs 4728-1700-27...
  • Page 23: Trouble Shooting Guide

    Poor cooling capacity Your help in collecting this information will greatly assist the Houghton service team in ● To make sure the filter is clean. correcting any problems - Thank you. ● Turn on the fan to high FAN to obtain the maximum...
  • Page 24: Circuit Diagram

    Circuit Diagram 240VAC 50Hz H2000/H2400 Circuit Diagram 240VAC 50Hz H2000C Circuit Diagram...
  • Page 25 115VAC 60Hz A2801 Circuit Diagram...
  • Page 26 V2 7388-2000-01...

This manual is also suitable for:

Belaire h2400Belaire a2801

Table of Contents