Houghton BELAIRE Owner's Manual page 10

Caravan air - conditioner
Hide thumbs Also See for BELAIRE:
Table of Contents

Advertisement

Install air flow separation baffle
A. Measure the height from ceiling to the steel base of the
air conditioner and trim the baffle to this height.
Baffle height
Ceiling to base height
Baffle height=Ceiling to base height
Connect the power supply
 It is the installers responsibility to ensure that local
wiring regulations are followed when connecting to
mains supply.
 The air conditioner shall be connected to a dedicated
supply circuit that can be isolated and has the correct
capacity.
 Look upward from inside the caravan and locate the
power cord as shown in the figure.
 Connect the external power lines to the 3-pole terminal
block and note the positions of the active, neutral and
ground.
Match the corresponding active, neutral and the ground
wire and firmly tighten up the screws to make sure the
power line is not loose or improperly connected, otherwise
a short circuit or fire could be caused.
Note
B.
Insert the trimmed air flow separation baffle into the
slot of the plenum mounting bracket.
7
Slot

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

A3501T3500A3800

Table of Contents