4.0 - PINOUT TABLES

4.1 - 20-PIN CONNECTOR

POSITION
WIRE FUNCTION
- 1 -
System arming confirmation signal
- 2 -
System disarming confirmation signal
- 3 -
- 4 -
- 5 -
Door switches - Positive/negative input
Touch key receptacle input
- 6 -
Touch key receptacle ground
- 7 -
LED negative output
- 8 -
LED positive output
- 9 -
Ignition
- 10 -
- 11 -
CAN BUS (CAN-H) signal
- 12 -
CAN BUS (CAN-L) signal
Positive output - System armed (+A)
- 13 -
External sensors negative input
- 14 -
Bonnet switch negative input
- 15 -
Hazard lights or negative outut during alarm (siren,
- 16 -
pager, tracker)
Lock command (1,5 sec.* negative pulse when pressing
- 17 -
remote control button "1" or "3")
Unlock command (1 sec. negative pulse when pressing
- 18 -
remote control button "2")
- 19 -
Input for learning and arming/disarming via turn
- 20 -
indicator flashes
* If this function is enabled, the lock/unlock pulse will be
4.2 - 8-PIN CONNECTOR
POSITION
WIRE FUNCTION
- 1 -
Ground
- 2 -
Siren output
- 3 -
Positive supply
- 4 -
Turn indicators positive output
- 5 -
Engine immobilizer
- 6 -
Siren output
- 7 -
Engine immobilizer
- 8 -
Turn indicators positive output
For more complete information regarding connections, refer to the
models
installation instructions at
PAGE 08 - INSTALLER MANUAL
WIRE COLOR
-----
YELLOW-BLUE
GREEN-BLUE
-----
GREEN-BROWN
BLACK marked "G"
LIGHT BLUE-GREY
LIGHT BLUE
GREEN-BLACK
WHITE-BLACK
YELLOW-BLACK
-----
WHITE-ORANGE
0,5 sec. instead of
1,5 sec.
WIRE COLOR
BLACK marked "M"
BLACK marked "R"
BLACK marked "H"
BLACK marked "H"
supported vehicle
www.gemini-alarm.com
(
private area).
electrical connections,
!
disconnect the battery
negative terminal and
reconnect again after
-----
TOUCH KEY
-----
GREEN
BROWN
BLACK
RED
Negative input - External sensors
PINK
Positive/negative input - Door switches
GREEN
BLUE
LIGHT BLUE-GREY (CAN-H)
Positive output -System armed (+A)
-----
Lock command (negative)
Unlock comand (negative)
-----
ORANGE
-----
ORANGE

5.0 - WIRING DIAGRAM

Before carrying out
completion.
Green
Brown
Red
Black
GREEN-BLACK
GREEN-BROWN
LIGHT BLUE (CAN-L)
CAN BUS signal
PINK
WHITE-BLACK
YELLOW-BLACK
YELLOW-BLUE
GREEN-BLUE
Input for system operation
via vehicle door
lock motor unit
BLUE
Hazard lights or
negative output during alarm
(siren, pager, tracker)
Connection to
supplied
siren
8
7
6
4
3
2
BLACK marked
"R"
15A
+
POSITIVE
Battery
BLACK marked
"M"
GROUND
ORANGE
ORANGE
Output - Turn indicators
BLACK marked "H"
BLACK marked "H"
Engine immobilizer
MAX !
WHITE-ORANGE
Input for system operation
via turn indicators
Bonnet switch
GREEN
+30
BLACK marked "G"
Ignition