Gemini 932 Series Installation And Use Manual

Gemini 932 Series Installation And Use Manual

Hide thumbs Also See for 932 Series:

Advertisement

932 SERIES
INSTALLATION AND
USE MANUAL
UK
Made in Italy
AC 2784 Rev. 05 - 12/12

Advertisement

Table of Contents
loading

Summary of Contents for Gemini 932 Series

  • Page 1 932 SERIES INSTALLATION AND USE MANUAL Made in Italy AC 2784 Rev. 05 - 12/12...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS - PRELIMINARY ADVICE..................... PAGE 03 USER MANUAL - OPERATING DESCRIPTION..................PAGE 03 2.1 - Complete system arming..................PAGE 03 2.2 - System arming with sensor and comfort control exclusion........PAGE 03 2.3 - Passive arming......................PAGE 03 2.4 - Arming delay......................
  • Page 3: Preliminary Advice

    Before installing, identify your alarm model and refer to it for the correct instructions GEMINI 932: same as 933 without self-powered battery. The following signs, intended for the installer or the user, indicate particular functions or connections as follows For the user.
  • Page 4: System Armed

    2.5 - SYSTEM ARMED After the arming delay, the system is fully armed and ready to detect any alarm condition. When the system is fully armed, the LED will start flashing. 2.6 - ALARM, NEUTRAL TIME BETWEEN ALARMS AND ALARM CYCLES An alarm condition is signalled by optical/ acoustic...
  • Page 5: Warranty Conditions

    The warranty will become void if labels are missing or torn, if the installation certificate is not fully compiled or if the enclosed sale document is missing. The guarantee is valid exclusively at authorized Gemini Technologies S.p.A. Service Centers. The manufacturer declines any responsibility for eventual malfunctions of the device or any damage to the vehicle electrical system due to improper installation, use or tampering.
  • Page 6: Installer Manual

    INSTALLER MANUAL 5.0 - PIN-OUT TABLES 5.1 - 20-PIN CONNECTOR WIRE COLOUR POSITION WIRE FUNCTION - 1 - ----- ----- - 2 - System arming signal YELLOW-BLUE - 3 - System disarming signal GREEN-BLUE - 4 - ----- ----- - 5 - Door trigger positive/negative input GREEN-BROWN - 6 -...
  • Page 7: Wiring Diagram

    6.0 - WIRING DIAGRAM Before carrying out electrical connections, disconnect the negative battery terminal. Re-connect ONLY after Connection completion. of 933 unit with supplied ELECTRONIC KEY siren Green Brown Black BLACK marked “R” GREEN-BLACK POSITIVE External sensors input Battery GREEN-BROWN BLACK marked “M”...
  • Page 8: Onnection For Turn Signals Activation

    ONNECTION FOR TURN SIGNALS ACTIVATION 7.1 - STANDARD CONNECTIONS LEFT TURN RIGHT TURN INDICATORS INDICATORS ORANGE GEMINI 933 ORANGE SYSTEM WHITE-ORANGE WHITE-ORANGE wire must ONLY be connected if the system is to operate through turn indicators. 7.2 - CONNECTIONS FOR VEHICLES WITH SEPARATE LINES...
  • Page 9: Connections To Arm/Disarm The System

    Refer to the wiring diagrams available for most makes and models of vehicle (www.gemini-alarm.com, restricted access section) The various arming modes are listed below and the connections indicated in the following paragraphs. Arming via CAN BUS line.
  • Page 10: Vehicle Code Programming

    ”). A separate leaflet, included in the alarm packaging, lists all the available vehicles (codes are updated at packaging time). Up-to-date information on supported vehicle models can be found at: www.gemini- alarm.com (restricted access section The system has a indicator that signals any wrong vehicle code inserted.
  • Page 11: Self-Learning Of Turn Indicators Flashes

    When the last digit is entered, the alarm system “repeats” the entered code. 1 FLASH AND A SHORT PAUSE 10 FLASHES AND A SHORT PAUSE 3 FLASHES Press the vehicle remote control lock/unlock buttons to make sure the alarm system works properly.
  • Page 12: System Programming

    Enabled Negative output during alarm cycle Disabled For Gemini only, turn ignition key ----- A lack of power during electrical system maintenance, will not affect the programming. The procedure must be carried out entirely. Every turn of the ignition key...
  • Page 13: Negative Output Selection (During Alarm) For Horn Or Additional Siren

    11.7 - NEGATIVE OUTPUT SELECTION (DURING ALARM) FOR HORN OR ADDITIONAL SIREN Once enabled, this function can activate the output for the siren (continuous tone) or for the horn (intermittent tone 12.0 - SYSTEM PROGRAMMING EXAMPLE Here below is an example that illustrates the various steps to follow to modify the programmable functions.
  • Page 14: Adding New Devices

    13.0 - ADDING NEW DEVICES To carry out the operation successfully, make sure the required electrical connections (bonnet switch and igntion) are complete. Storing memory is for 55 devices If an extra device is added, it automatically deletes the first device stored in the system memory.
  • Page 15: Deleting Programmed Devices

    14.0 - DELETING PROGRAMMED DEVICES To carry out the operation successfully, make sure the required electrical connections (bonnet switch and ignition) are complete. All previously programmed devices can be deleted. To clear memory proceed as follows. With the system disarmed, open the bonnet and leave it open The following operations must be carried out within 4 seconds otherwise the procedure is invalidated.
  • Page 16: Ultrasonic Volumetric Protection

    15.0 - ULTRASONIC VOLUMETRIC PROTECTION 15.1 - CO NNECTION AND POSITIONING nsert the WHITE connector in the “W” marked socket and the RED connector in the “R” marked socket (see figure below). Install the ultrasonic sensors on the top part of the windshield internal pillars, away from the air vents and point them towards the center of the rear window 15.2 - SENSOR ADJUSTMENT o check the sensitivity level proceed as follows...
  • Page 17: Technical Specifications

    17.0 - TECHNICAL SPECIFICATIONS Power supply 12 Vdc Current absorption @ 12Vdc with system armed and LED flashing 15 mA Working temperature range -30°C to +70°C Turn indicators relay contact capacity 8 A @ 20°C Engine immobiliser relay contact capacity 8 A @ 20°C Alarm cycle duration 30 sec.
  • Page 18 7 Dudley Court , Jessop Close, Clacton-on-Sea, Essex, CO15 4LY TEL: +44 (0) 1255 434353 Email: sales@avsgemini.com | Web: www.avsgemini.com UK Distributors of the Gemini Alarm Systems...

Table of Contents