Installer Manual; Pinout Tables; 20-Pin Connector; Complete Wiring Diagram - Gemini 933MH Installation And Use Manual

Table of Contents

Advertisement

INSTALLER MANUAL

4.0 - PINOUT TABLES

4.1 - 20-PIN CONNECTOR

POSITION
WIRE FUNCTION
- 1 -
- 2 -
- 3 -
- 4 -
- 5 -
Positive/negative input - door switches
- 6 -
Input - electronic key receptacle
- 7 -
Ground - electronic key receptacle
- 8 -
LED negative output
- 9 -
LED positive output
- 10 -
Ignition
- 11 -
CAN BUS (CAN-H) signal
- 12 -
CAN BUS (CAN-L) signal
- 13 -
Positive output - system armed (+A)
- 14 -
Negative input - external sensors
- 15 -
Negative input - bonnet switch
Output for self-powered siren (lack of negative during
- 16 -
alarm) or optical pulse signals
Lock command (1,5" negative pulse when pressing
- 17 -
remote control button "1" or "3")
Unlock command (1,5" negative pulse when pressing
- 18 -
remote control button "2")
- 19 -
- 20 -
4.2 - 8-PIN CONNECTOR
POSITION
WIRE FUNCTION
- 1 -
Ground
- 2 -
Siren output
- 3 -
Positive supply
- 4 -
Positive output - turn indicators
- 5 -
Engine immobilization
- 6 -
Siren output
- 7 -
Engine immobilization
- 8 -
Positive output - turn indicators
For complete information regarding connections, please refer to your vehicle wiring
PAGE 06 - INSTALLER MANUAL
WIRE COLOUR
-----
-----
-----
-----
GREEN-BROWN
BLACK marked "G"
LIGHT BLUE-GREY
LIGHT BLUE
GREEN-BLACK
WHITE-BLACK
YELLOW-BLACK
-----
-----
WIRE COLOUR
BLACK marked "M"
BLACK marked "R"
BLACK marked "H"
BLACK marked "H"
diagram.
electrical connections,
!
disconnect the negative
battery terminal and re-
-----
-----
-----
ELECTRONIC KEY
-----
GREEN
BROWN
BLACK
RED
Negative input - external sensors
PINK
Positive/negative input - door switches
GREEN
BLUE
LIGHT BLUE-GREY (CAN-H)
Positive output - system armed (+A)
-----
-----
Lock command (negative)
Unlock command (negative)
-----
ORANGE
-----
ORANGE

5.0 - COMPLETE WIRING DIAGRAM

Before carrying out
connect again after
completion.
Green
Brown
Red
Black
GREEN-BLACK
GREEN-BROWN
LIGHT BLUE (CAN-L)
CAN BUS signal
PINK
WHITE-BLACK
YELLOW-BLACK
BLUE
Self-powered siren output
(art. 7725, lack of negative
in alarm) or
optical pulse signals
Connection of unit
933MH
with supplied siren
8
7
6
4
3
2
BLACK marked "R"
15A
+
POSITIVE
Battery
BLACK marked "M"
GROUND
ORANGE
ORANGE
Output - turn indicators
"H"
BLACK marked
"H"
BLACK marked
Engine immobilization
MAX !
Bonnet switch
GREEN
+30
BLACK marked "G"
Ignition
INSTALLER MANUAL - PAGE 07
5
1
8A

Advertisement

Table of Contents