Gas Furnace Set Up - Daikin REYQ-XA Service Manual

Table of Contents

Advertisement

Field Settings for Indoor Unit
1.4

Gas Furnace Set Up

Set-up for gas furnace is possible only by using the DIP switches located on CXTQ-TA.
Gas furnace's DIP switch is not valid. Refer to the gas furnace's installation manual for details of each setting
menu.
Note:
If the Heat OFF Delay time was changed to a longer time, warm-up process time of the heat pump might be
longer.
Purpose
Heat Airflow Trim
Heat ON Delay
Heat OFF Delay
Heating
Speed Tap
185
Function
Modulating
2-Stage
Dip switch
–15%
–10%
–12%
–8%
–9%
–6%
–6%
–4%
–3%
–2%
0%
0%
+3%
+2%
+6%
+4%
+9%
+6%
+12%
+8%
+15%
+10%
0%
0%
0%
0%
0%
Dip switch
5 sec.
10 sec.
15 sec.
20 sec.
25 sec.
30 sec.
30 sec.
30 sec.
Dip switch
30 sec.
60 sec.
90 sec.
120 sec.
150 sec.
180 sec.
150 sec.
150 sec.
Dip switch
A
B
C
D
Position
1
2
DS1
OFF
OFF
ON
OFF
OFF
ON
ON
ON
OFF
OFF
ON
OFF
OFF
ON
ON
ON
OFF
OFF
ON
OFF
OFF
ON
ON
ON
OFF
OFF
ON
OFF
OFF
ON
ON
ON
DS2
OFF
OFF
ON
OFF
OFF
ON
ON
ON
OFF
OFF
ON
OFF
OFF
ON
ON
ON
DS3
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
OFF
ON
OFF
ON
ON
ON
ON
ON
DS3
Field Settings and Test Operation
SiUS371901E
: Factory setting
3
4
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
OFF
ON
OFF
ON
OFF
ON
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
DS2
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
ON
ON
ON