Sign In
Upload
Manuals
Brands
Daikin Manuals
Temperature Controller
REYQ72-432XA YCU
Daikin REYQ72-432XA YCU Manuals
Manuals and User Guides for Daikin REYQ72-432XA YCU. We have
1
Daikin REYQ72-432XA YCU manual available for free PDF download: Service Manual
Daikin REYQ72-432XA YCU Service Manual (441 pages)
Brand:
Daikin
| Category:
Temperature Controller
| Size: 14.84 MB
Table of Contents
Part 1 General Information
14
Table of Contents
14
1 Model Names
15
Indoor Unit
15
Outdoor Unit
16
Air Treatment Equipment
17
Branch Selector Unit
17
2 External Appearance
18
Indoor Unit
18
Outdoor Unit
19
Air Treatment Equipment
20
Branch Selector Unit
20
3 Combination of Outdoor Units
21
Reyq-Xatju, Reyq-Xaydu, Reyq-Xaycu
21
4 Capacity Range
22
Connection Ratio
22
Outdoor Unit Combinations
22
Limitation of Capacity Index for Heat Recovery
23
5 Specifications
24
Reyq-Xatju
24
Reyq-Xaydu
41
Reyq-Xaycu
58
Refrigerant Circuit Part 2
74
1 Refrigerant Circuit
75
Outdoor Unit
75
Refrigerant Circuit Part
75
Indoor Unit
78
Outdoor-Air Processing Unit
80
Branch Selector Unit
81
2 Functional Parts Layout
87
Reyq72/96/120Xatju, Reyq72/96/120Xaydu, Reyq72/96/120Xaycu
87
Reyq144/168Xatju, Reyq144/168Xaydu, Reyq144/168Xaycu
89
3 Refrigerant Flow for each Operation Mode
91
Cooling Operation
91
Heating Operation
92
Simultaneous Cooling and Heating Operation
93
Cooling Oil Return Operation
94
Defrost Heating Oil Return Operation
95
Oil Return Operation at Simultaneous Cooling and Heating Operation
96
Part 3 Remote Controller
97
1 Applicable Models
98
2 Names and Functions
99
Brc1E73
99
Wireless Remote Controller
102
3 Main/Sub Setting
103
Brc1E73
103
When Wireless Remote Controller Is Used Together
104
4 Address Setting for Wireless Remote Controller
105
5 Centralized Control Group No. Setting
107
Brc1E73
107
Wireless Remote Controller
109
Group No. Setting Example
110
6 Service Settings Menu, Maintenance Menu
111
Brc1E73
111
Part 4 Functions and Control
115
1 Function General
117
Outdoor Unit
117
Branch Selector Unit & Indoor Unit Operation Mode Detail
118
2 Stop Control
119
Stop Due to Error
119
When System Is in Stop Control
119
Slave Unit Stops During Master Unit Control
119
3 Standby Control
120
Restart Standby
120
Crankcase Heater Control
120
4 Startup Control
121
Startup Control in Cooling
121
Startup Control in Heating
122
5 Basic Control
123
Normal Control
123
Compressor PI Control
124
Compressor Step Control
125
Electronic Expansion Valve PI Control
127
Step Control of Outdoor Fans
128
Heat Exchanger Control
129
6 Protection Control
130
High Pressure Protection Control
130
Low Pressure Protection Control
132
Discharge Pipe Protection Control
133
Compressor Body Protection Control
134
Inverter Protection Control
134
7 Special Control
136
Pump down Residual Control
136
Oil Return Control
137
Defrost Control
140
Outdoor Unit Rotation
141
Cooling/Heating Mode Switching
142
8 Other Control
146
Backup Operation
146
Demand Operation
146
Heating Operation Prohibition
146
9 Outline of Control (Indoor Unit)
147
Operation Flowchart
147
Set Temperature and Control Temperature
151
Remote Controller Thermistor
153
Thermostat Control
155
Drain Pump Control
158
Control of Electronic Expansion Valve
160
Freeze-Up Prevention
161
List of Swing Flap Operations
163
Hot Start Control (in Heating Only)
164
Louver Control for Preventing Ceiling Dirt
165
Heater Control (Except FXTQ-TA Models)
166
Heater Control (FXTQ-TA Models)
167
Gas Furnace Control (CXTQ-TA Models)
170
3-Step Thermostat Processing (FXTQ-TA Models)
171
Fan Control (Heater Residual) (FXTQ-TA Models)
172
Interlocked with External Equipment (FXTQ-TA and CXTQ-TA Models)
172
Part 5 Field Settings and Test Operation
174
1 Field Settings for Indoor Unit
175
Field Settings with Remote Controller
175
List of Field Settings for Indoor Unit
179
Details of Field Settings for Indoor Unit
183
Gas Furnace Set up
198
List of Field Settings for Outdoor-Air Processing Unit
199
Setting of Operation Control Mode
199
2 Field Settings for Outdoor Unit
201
DIP Switch Setting Mounting a Spare PCB
201
Accessing the BS Buttons on the PCB
203
Operating the BS Buttons and DIP Switches on the PCB
204
Connecting the PC Configurator to the Outdoor Unit
207
Monitoring Function and Field Settings
208
Cool/Heat Mode Changeover
230
Night-Time Low Noise Operation and Demand Operation
231
3 Test Operation
236
Checks before Test Operation
236
Checkpoints
236
Gas Furnace Test Operation
237
Part 6 Service Diagnosis
238
1 Symptom-Based Troubleshooting
241
Indoor Unit Overall
241
With Gas Furnace
244
Gas Furnace Lockout Reset
244
With Optional Infrared Presence/Floor Sensor
245
2 Troubleshooting with Remote Controller
246
Wired Remote Controller
246
Wireless Remote Controller
247
3 Troubleshooting by Error Code
249
Error Codes and Descriptions
249
Error Codes (Sub Codes)
251
External Protection Device Abnormality
264
Indoor Unit Control PCB Abnormality
266
Drain Level Control System Abnormality
267
Indoor Fan Motor Lock, Overload
269
Indoor Fan Motor Abnormality
271
Overload/Overcurrent/Lock of Indoor Fan Motor
275
Blower Motor Not Running
276
Indoor Fan Motor Status Abnormality
277
Low Indoor Airflow
278
Swing Flap Motor Abnormality
279
Power Supply Voltage Abnormality
281
Blower Motor Stops for Over/Under Voltage
282
Electronic Expansion Valve Coil Abnormality, Dust Clogging
283
Gas Furnace Abnormality
284
Drain Level above Limit
285
Capacity Determination Device Abnormality
286
Transmission Abnormality between Indoor Unit Control PCB and Fan PCB
287
Blower Motor Communication Error
289
Climate Talk Communication Error
290
Thermistor Abnormality
291
Combination Error between Indoor Unit Control PCB and Fan PCB
292
Blower Motor HP Mismatch
293
Indoor Blower Does Not Have Required Parameters to Function
294
Remote Sensor Abnormality
295
Humidity Sensor System Abnormality
296
Infrared Presence/Floor Sensor Error
297
Remote Controller Thermistor Abnormality
302
Outdoor Unit Main PCB Abnormality
303
Detection of Ground Leakage by Leak Detection Circuit
304
Missing of Ground Leakage Detection Core
305
Activation of High Pressure Switch
306
Activation of Low Pressure Sensor
308
Compressor Motor Lock
309
Compressor Damage Alarm
311
Outdoor Fan Motor Abnormality
313
Electronic Expansion Valve Coil Abnormality
317
Discharge Pipe Temperature Abnormality
318
Wet Alarm
320
Refrigerant Overcharged
322
Branch Selector Unit Electronic Expansion Valve Abnormality
323
Harness Abnormality (between Outdoor Unit Main PCB and Inverter PCB)
324
Outdoor Fan Motor Signal Abnormality
325
Outdoor Fan PCB Abnormality
326
Thermistor Abnormality
327
High Pressure Sensor Abnormality
329
Low Pressure Sensor Abnormality
330
Inverter PCB Abnormality
331
Momentary Power Failure During Test Operation
333
Reactor Temperature Rise Abnormality
334
Inverter Radiation Fin Temperature Rise Abnormality
335
Compressor Instantaneous Overcurrent
338
Compressor Overcurrent
340
Compressor Startup Abnormality
342
Transmission Error between Inverter PCB and Outdoor Unit Main PCB
344
Power Supply Voltage Imbalance
346
Reactor Surface Thermistor Abnormality
348
Inverter Radiation Fin Temperature Abnormality
349
Field Setting after Replacing Outdoor Unit Main PCB Abnormality or Combination of PCB Abnormality
351
Refrigerant Shortage
352
Reverse Phase, Open Phase
353
Power Supply Insufficient or Instantaneous Abnormality
355
Check Operation Not Executed
357
Transmission Error between Indoor Units and Outdoor Units, Open Phase in Power Supply Wiring
358
Transmission Error between Remote Controller and Indoor Unit
361
Transmission Error between Outdoor Units
362
Transmission Error between Main and Sub Remote Controllers
368
Transmission Error between Indoor Units and Outdoor Units in the same System
369
Improper Combination of Indoor, Branch Selector and Outdoor Units
370
Incorrect Gas Furnace Connecting Number
377
Incorrect Electric Heater Capacity Setting
378
Address Duplication of Centralized Controller
379
Transmission Error between Centralized Controller and Indoor Unit
380
System Not Set yet
382
System Abnormality, Refrigerant System Address Undefined
383
Climate Talk Communication System Combination Error (before Initial Setting for Communication Completes)
385
Climate Talk Communication System Combination Error
385
(After Initial Setting for Communication Completes)
386
4 Check
387
High Pressure Check
387
Low Pressure Check
388
Superheat Operation Check
389
Power Transistor Check
390
Refrigerant Overcharge Check
395
Refrigerant Shortage Check
396
Vacuuming and Dehydration Procedure
397
Thermistor Check
398
Pressure Sensor Check
401
Broken Wire Check of the Relay Wires
402
Fan Motor Connector Check (Power Supply Cable)
403
Fan Motor Connector Check (Signal Cable)
404
Electronic Expansion Valve Coil Check
406
Fan Motor Connector Check for FXTQ-TA
409
Wiring Diagrams
414
Outdoor Unit
414
Indoor Unit
419
Air Treatment Equipment
433
Branch Selector Unit
436
Advertisement
Advertisement
Related Products
Daikin REYQ72-456XA YDU
Daikin REYQ-XA
Daikin REYQ72-456TATJU
Daikin REYQ72-456TAYDU
Daikin REYQ72-456XATJU
Daikin REYQ72-456XATJUA
Daikin REYQ72-456XAYDU
Daikin REYQ72-456XAYDUA
Daikin REYQ72-432XAYCU
Daikin REYQ72-432XAYCUA
Daikin Categories
Air Conditioner
Heat Pump
Remote Control
Chiller
Fan
More Daikin Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL