Daikin EHBH04CB Operation Manual

Daikin EHBH04CB Operation Manual

Daikin altherma - low temperature split
Hide thumbs Also See for EHBH04CB:

Advertisement

Operation manual
Daikin Altherma – Low temperature split
EHBH04CB
EHBH08CB
EHBH11CB
EHBH16CB
EHBX04CB
EHBX08CB
EHBX11CB
EHBX16CB
                                   
EHVH04S18CB
EHVH08S18CB
EHVH08S26CB
EHVH11S18CB
EHVH11S26CB
EHVH16S18CB
EHVH16S26CB
EHVX04S18CB
EHVX08S18CB
EHVX08S26CB
EHVX11S18CB
EHVX11S26CB
Operation manual
EHVX16S18CB
English
Daikin Altherma – Low temperature split
EHVX16S26CB

Advertisement

Table of Contents
loading

Summary of Contents for Daikin EHBH04CB

  • Page 1 Operation manual Daikin Altherma – Low temperature split EHBH04CB EHBH08CB EHBH11CB EHBH16CB EHBX04CB EHBX08CB EHBX11CB EHBX16CB                                     EHVH04S18CB EHVH08S18CB EHVH08S26CB EHVH11S18CB EHVH11S26CB EHVH16S18CB EHVH16S26CB EHVX04S18CB EHVX08S18CB EHVX08S26CB EHVX11S18CB EHVX11S26CB Operation manual EHVX16S18CB English Daikin Altherma – Low temperature split EHVX16S26CB...
  • Page 2: Table Of Contents

    Digital files on http:// Components in a typical system layout ........reference instructions and background www.daikineurope.com/ guide information for basic and support­and­manuals/ 3 Operation advanced usage product­information/. Overview: Operation..............The user interface at a glance ........... Latest revisions of the supplied documentation may be available on 3.2.1 Buttons................ the regional Daikin website or via your installer. 3.2.2 Status icons ..............The original documentation is written in English. All other languages Space heating/cooling control ........... are translations. 3.3.1 Setting the space operation mode ......3.3.2 Using the room temperature home page ....Available screens 3.3.3 Using the leaving water temperature home pages Depending on your system layout and installer configuration, not all (main + additional) ............screens in this document may be available on your user interface.
  • Page 3: Operation

     HOME PAGES At the next scheduled action, the desired temperature ▪ Switches between home pages (when you are on a home will NOT change. page). At the next scheduled action, the desired temperature ▪ Goes to the default home page (when you are in the menu will decrease. structure).  MALFUNCTION INFORMATION The preset value (Comfort or Eco) or scheduled value If a malfunction occurs,   is displayed on the home pages. is temporarily overruled. Press   to display more information about the malfunction. The DHW tank booster mode is active or ready to be  ON/OFF activated. Turns  ON  or  OFF  one  of  the  controls  (room  temperature, Quiet mode is active. leaving water temperature, DHW tank temperature). Holiday mode is active or ready to be activated. Child lock mode and/or function lock mode is active. EHBH/X04~16CB + EHVH/X04~16CB Operation manual Daikin Altherma – Low temperature split 4P383117­1C – 2015.01...
  • Page 4: Space Heating/Cooling Control

    Configuring  user  profile  and  home  pages  in  the  user  reference temperature  shown  on  the  DHW  tank  temperature  home  page guide. (example: 50°C). User profile = Basic User profile = Detailed 15:20 15:20 60°C 20.0°C Room Room 50°C 40°C Actual temperature 20.0°C Scheduled 17:30 Actual temperature 15°C 00:00 07:00 14:00 21:00 DHW tank temperature Time Operation manual EHBH/X04~16CB + EHVH/X04~16CB Daikin Altherma – Low temperature split 4P383117­1C – 2015.01...
  • Page 5: Scheduled Mode

    Storage comfort The  user  permission  level  will  stay  in  Adv.  end  user  until  set 50°C Storage eco otherwise. 45°C Reheat 35°C Reheat tank temperature – hysteresis value To set the user permission level to End user 1 Press   for more than 4 seconds. Result:  The  user  permission  level  switches  to  End  user.  The  user interface will return to the default home screen. EHBH/X04~16CB + EHVH/X04~16CB Operation manual Daikin Altherma – Low temperature split 4P383117­1C – 2015.01...
  • Page 6: Schedules: Example

    2 Select  User  defined  1,  User  defined  2  or  User  defined  3  and press  3 Change  the  name  and  press  .  (Only  applicable  for  room temperature schedules). Example: MyWeekSchedule To select which schedule you currently want to use 1 Go to [5]:   > Select schedules. 2 Select for which control you want to use a schedule. Example: [5.1] Room temperature. 3 Select  for  which  operation  mode  you  want  to  use  a  schedule. Example: [5.1.1] Heating. 4 Select a predefined or user­defined schedule and press  Operation manual EHBH/X04~16CB + EHVH/X04~16CB Daikin Altherma – Low temperature split 4P383117­1C – 2015.01...
  • Page 7: Menu Structure: Overview User Settings

    Quiet mode DHW pump [7.4] Preset values Room temperature LWT main Tank temperature Quiet level [7.7] Set weather dependent Main [7.7.1] Main Additional Set weather-dependent heating Set weather-dependent cooling [7.7.2] Additional Set weather-dependent heating Set weather-dependent cooling EHBH/X04~16CB + EHVH/X04~16CB Operation manual Daikin Altherma – Low temperature split 4P383117­1C – 2015.01...
  • Page 8 3.8.2 Space heating/cooling control ▪ For  longer  periods:  You  can  use  the  holiday  mode.  Example: When  you  stay  at  home  during  your  holiday,  or  when  you  go Setting Default Fill in… away during your holiday. Leaving water temperature: Main zone [A.3.1.1] LWT setpoint mode 1 (WD) Leaving water temperature: Additional zone [A.3.1.2] LWT setpoint mode 1 (WD) Leaving water temperature: Delta T source [A.3.1.3] Operation manual EHBH/X04~16CB + EHVH/X04~16CB Daikin Altherma – Low temperature split 4P383117­1C – 2015.01...
  • Page 9: Troubleshooting

    DHW  tank  to  a  preset  value  ( Prerequisite:  You  switched  the  permission  level  to  Advanced  end Storage  eco  =  lower  tank user. temperature) during the day. 1 Go  to  [6.3.2]:    >  Information  >  Error  handling  >  Contact/ helpdesk number. EHBH/X04~16CB + EHVH/X04~16CB Operation manual Daikin Altherma – Low temperature split 4P383117­1C – 2015.01...
  • Page 10 ▪ Call  your  local  dealer  to  get the heat pump fixed. INFORMATION When  the  backup  heater  takes  over  the  heat  load, electricity consumption will be considerably higher. Glossary DHW = Domestic hot water Hot  water  used,  in  any  type  of  building,  for  domestic purposes. LWT = Leaving water temperature Water temperature at the water outlet of the heat pump. Operation manual EHBH/X04~16CB + EHVH/X04~16CB Daikin Altherma – Low temperature split 4P383117­1C – 2015.01...
  • Page 12 4P383117-1 C 0000000 4P383117­1C  2015.01...