Circulating fan kit

Advertisement

Available languages

Available languages

2.
Connect the fan to the receiver.
a) Pull the fan control wire from the inside back of
the appliance along to the receiver.
Fan
control
wire
Connect
fan control
wire to
receiver
b) Detach the receiver from the Velcro and plug in
the fan control wire in the 6-pin connection at
the bottom of the receiver as indicated below.
Reinstall the receiver in the firebox.
on top
at bottom
CONNECT
FAN HERE
Fan connector
Connect the fan control
wire to the receiver here
3.
Plug the fan into an electrical outlet.
Test the fan
The fan is operated with the remote control system. It
has 4 speed levels. On the remote control handset's
display, this icon (
(
high.
1.
2.
3.
4.
NOTE: 8 seconds after the fan has been set, the
Remote Control Receiver
) represent the fan and this icon
) represents the speed. One bar is low, four bars is
Add a 1 9 V battery to the remote control handset.
On the remote handset, briefly press the SET
button to fan mode (
Press the large flame button (
fan function and increase its speed.
Press the small flame button (
fan speed or to switch the fan OFF.
remote handset will automatically go into
temperature control mode (TEMP). The fan
starts 4 minutes after the gas opens (from OFF
or from pilot) at maximum speed and goes to
the displayed level after 4 seconds. The fan
stops 10 minutes after the gas is OFF or at pilot.
Setting Fan
Fan Set indicated on handset display
). The fan icon flashes.
) to activate the
) to decrease the
Fan icon
Fan speed
icon
FASTER
SLOWER,
TO OFF