Download Print this page

Valor G4 Series Installation And Operating Instructions Manual page 6

Circulating fan kit

Advertisement

Available languages

Available languages

Access for servicing—785 fireplace
WARNING
DO NOT TOUCH THE FIREPLACE WHILE IT IS
HOT! Let it cool first before any maintenance.
Before carrying out any maintenance, make sure the
fireplace is turned off including the pilot.
MAKE SURE THE FIREPLACE IS COLD!
Accessing the fan
1.
Access the fan from the rear of the firebox.
a) Remove the front, trim, and other accessory
necessary to have access to the gas valve
on the left hand side of the appliance and the
window. See the instruction manual supplied
with the 785 appliance.
b) Below the gas valve, turn the switch off (O) so
the fireplace does not start accidentally.
c) Detach the vent plate from the top of the
fireplace (2 screws) and slide it out of the
firebox.
d) Pull the appliance out of the cavity. You need
access to the left-hand side and the rear of the
appliance.
2.
Remove the left side valve access panel (5
screws).
3.
Disconnect the fan from electric power.
WARNING
TO AVOID ELECTRIC SHOCK disconnect the
power to the fan before servicing.
6
4.
Carefully disconnect the fan control wire from the
receiver.
Fan
control
wire
Disconnect
fan control
wire from
receiver
5.
At the rear of the appliance, remove the fan box (9
screws).
You can now clean the fan enclosure and the fan cavity
at the back of the appliance. Take this opportunity to
clean the back of the appliance as well.