3.9

Thermal Management

A heatspreader plate assembly is available from Kontron Embedded Modules for the microETXexpress®-DC. The
heatspreader plate on top of this assembly is NOT a heat sink. It works as a COM Express®-standard thermal interface to
use with a heat sink or other cooling device.
External cooling must be provided to maintain the heatspreader plate at proper operating temperatures. Under worst-
case conditions, the cooling mechanism must maintain an ambient air and heatspreader plate temperature of 60° C or
less.
The aluminum slugs and thermal pads on the underside of the heatspreader assembly implement thermal interfaces
between the heatspreader plate and the major heat-generating components on the microETXexpress®-DC. About 80
percent of the power dissipated within the module is conducted to the heatspreader plate and can be removed by the
cooling solution.
You can use many thermal-management solutions with the heatspreader plates, including active and passive approaches.
The optimum cooling solution varies, depending on the COM Express® application and environmental conditions. Please
see the COM Express® Design Guide for further information on thermal management.
3.10

Heatspreader

Documentation and CAD drawings of microETXexpress®-DC heatspreader and cooling solutions is provided at
http://emdcustomersection.kontron.com.