Operation With Charging Electronics - oventrop i-Tronic TFC Installation And Operating Instructions Manual

Climate meter with integrated temperature, air humidity and co2 sensor
Table of Contents

Advertisement

Available languages

Available languages

„i-Tronic TFC"
3.3

Operation with charging electronics

Power supply of this "i-Tronic TFC"
model
is
carried
rechargeable batteries (2 x AA NiMH)
integrated in the table stand. This
allows for the mobile monitoring of the
room climate variables temperature,
humidity and CO
2
Operating time of the rechargeable
batteries: about 6 days
The batteries can be charged via a
mains adaptor with micro USB cable
which is plugged into the table stand.
Technical data "charging electronics"
Power supply
Rechargeable
batteries
Charging/battery
operation
Charging cycles
Protection
Protective system
Ambient temperature
Colour of casing
Dimensions (W/H/D)
out
via
two
content.
Micro USB with 5V DC
min. 500mA
Rechargeable Mignon cells / 2xHR6 / AA /
1,900-2,700mA / NiMH
about 12 h / > about 6 days (display lighting
5x/day; Charging capacity of battery >95%,
age related)
up to 1.000
IP 20 (EN 60529)
III-Protective low voltage
+5°C up to +40°C
RAL 9016 traffic white
70 / 110 / 57 mm
Installation and initial operation
21

Advertisement

Table of Contents
loading

Table of Contents