Transport And Storage; Installation; Operation; Temperature Limitation - oventrop Uni FHU Operating Instructions Manual

Thermostat with remote control
Table of Contents

Advertisement

Available languages

Available languages

Transport and storage

Heating water
temperature
4.
Transport and storage
Transport the product in its original packaging.
Store the product under the following conditions:
Temperature
range
Relative air hu-
midity
Particles
Mechanical influ-
ences
Radiation
Chemical influ-
ences
5.

Installation

1. Remove the cover (see Illustr. 1 on page 16 (4)).
2. Fix the wall mounting device onto the wall at the desired position. Make
sure that a good circulation of air around the sensor is guaranteed and
that it is not thermally influenced (e.g. direct solar radiation).
3. Fit the control piston to the valve of the "Unibox". Observe the separate
operating instructions of the "Unibox".
Take care not to kink or flatten the capillary. The surplus length of
capillary can be coiled around the lower part of the sensor.
4. Refit the cover.
6.

Operation

6.1

Temperature limitation

The thermostat "Uni FHU" features two limiting elements which you can use
to define your individual comfort temperature range/temperature.
To prevent unauthorised tampering, any temperature setting of the thermo-
stat can be locked.
18
max. +120°C
-10°C to +50°C
Max. 95%
Store dry and free from dust
Protected from mechanical agitation
Protected from UV rays and direct sunlight
Do not store together with solvents, chemicals, acids,
fuels or similar substances
Uni FHU
101259580-V01.01.2020

Advertisement

Table of Contents
loading

Table of Contents