Torque Settings & Ip - ADJ HYDRO WASH X7 User Instructions

Hide thumbs Also See for HYDRO WASH X7:
Table of Contents

Advertisement

TORQUE SETTINGS & IP TESTER
TORQUE SETTINGS FOR SCREWS
ALL SCREWS MUST BE TIGHTENED WITH A TORQUE DRIVER. All screws
are Allen Head screws. Please see below for screw locations, screw quantity
and torque settings. The number listed in the "#" column corresponds to the
location on the fixture. See the fixture diagram and numbers on the next page
for SCREW LOCATIONS.
#
1
Lens Assembly to Head Casting (6x)
2
Lamp Cover to Head Casting
3
Yoke Arm Cover to Yoke Frame (8x Each Side = 16 Total) 6.5 - 8.7 In-Lb
4
Access Cover to Yoke Frame (4x)
5
Handle to Base Casting (2x Each Side = 4 Total)
6
Bottom Cover to Base Casting (12x)
7
Power & Data Connector to Base Casting (10x)
8
1/4 Turn Adapter Plate to Bottom Cover (16x)
TORQUE DRIVERS (Recommended):
UTICA TS-30 (Shown)
ALTERNATIVE DRIVERS:
Proto J6107A
Wiha 28887
CAUTION! DO NOT OVER TORQUE SCREWS AS THIS CAN CAUSE LEAKAGE ISSUES!TO
CONFIRM THE IP65 INTENGRITY AFTER A LAMP REPLACEMENT, TEST THE FIXTURE
USING THE ELATION IP TESTER. CONTACT ELATION SERVICE FOR MORE DETAILS.
SCREW LOCATIONS
SCREW TORQUE SETTINGS
6.5 - 8.7 In-Lb
6.5 - 8.7 In-Lb
Fasten via Manual Screwdriver
Fasten via Pneumatic Screwdriver
6.7 - 9.6 In-Lb
6.5 - 8.7 In-Lb
6.5 - 8.7 In-Lb