ADJ HYDRO WASH X7 User Instructions page 23

Hide thumbs Also See for HYDRO WASH X7:
Table of Contents

Advertisement

SYSTEM MENU
MAIN MENU
SUB MENU
Fixture Life Time
Total LED Time
Fixture Temps
Information
Humidity
Fan Info. (RPM)
DMX Values(3)
(See Note 3)
Error Logs
Max Temp
LED ON
High Temp LED
OFF
Software Version
(1) Current Maximum Temperature - Maximum temp. that has been recorded, before reset and after reset.
(2) Maximum Temperature - Overall maximum temp. that has been recorded. (Not Resettable)
(3) DMX Value settings depend on the DMX Channel mode the fixture is set to.
(4) Max Temp LED ON - Normal Operating Temperature
(5) Max Temp LED OFF - Normal Operating Temperature
OPTIONS / VALUES (Default Settings in BOLD)
Power On Time - XXXXXX Hours
P-On Time-R - XXXXXX Hours
P-On Time Reset - Pass Code = 050
LED On Time - XXXXXX Hours
LED On Time-R - XXXXXX Hours
LED On Time Reset - Pass Code = 050
Current: XXX ˚F / XXX ˚C
Max Resettable: XXX ˚F / XXX ˚C
LEDs
Max Not Resettable: XXX ˚F / XXX ˚C
Current: XXX ˚F / XXX ˚C
Max Resettable: XXX ˚F / XXX ˚C
Head
Max Not Resettable: XXX ˚F / XXX ˚C
Current: XXX ˚F / XXX ˚C
Max Resettable: XXX ˚F / XXX ˚C
Base
Max Not Resettable: XXX ˚F / XXX ˚C
Reset LED Temp: Pass Code = 050
Reset Head Temp: Pass Code = 050
Reset Base Temp: Pass Code = 050
Head Humidity: XXX%
Base Humidity: XXX%
LED Fan: XXXX
Base Fan: XXXX
Arm Fan: XXXX
Pan / Pan Fine / Tilt / Tilt Fine / Color / Color Mac-
ros / Red 1-7 / Green 1-7 / Blue 1-7 / White 1-7 /
Shutter / Dimmer / Dimmer Fine / Zoom / Dimmer
Modes / P/T Speed / Spe. Func
Fixture Errors (Listed Errors One by One)
Reset Error Log: Yes / No (Pass Code = 050)
32~169˚F, 99˚F(4) / 0~76˚C, 37˚C(4)
(See Note 4 below)
170˚F, 99˚F(5) / 77˚C, 37˚C(5)
(See Note 5 below)
VX.X
23
DESCRIPTION
Total Running Time (Not Resettable)
Total Running Time (Resettable)
Reset Total Running Time
Total LED On Running Time
(Not Resettable)
LED On Running Time (Resettable)
Reset LED Running Time
Current LED Temperature
Maximum Temperature(1)
Reached (Resettable)
(See Note 1)
Maximum Temperature(2)
Reached (Not Resettable)
(See Note 2)
Current Head Temperature
Maximum Temperature(1)
Reached (Resettable)
(See Note 1)
Maximum Temperature(2)
Reached (Not Resettable)
(See Note 2)
Current Base Temperature
Maximum Temperature(1)
Reached (Resettable)
(See Note 1)
Maximum Temperature(2)
Reached (Not Resettable)
(See Note 2)
Reset LED Temperature
(Max Resettable)
Reset Head Temperature
(Max Resettable)
Reset Head Temperature
(Max Resettable)
Current Head Humidity
Current Base Humidity
Current LED Fan Speed
Current Base Fan Speed
Current Arm Fan Speed
Current DMX Values
Last 10 Fixture Error Codes
Clear the Error Log
Fixture Temp. (LED On)
Fixture Temp. (LED Off)
Current Software Version

Advertisement

Table of Contents
loading

Table of Contents