Torque Settings & Ip Tester - ADJ HYDRO WASH X7 User Instructions

Hide thumbs Also See for HYDRO WASH X7:
Table of Contents

Advertisement

Hydro Wash X7
TORQUE SETTINGS FOR SCREWS
ALL SCREWS MUST BE TIGHTENED WITH A TORQUE DRIVER. All screws are Allen Head
screws. Please see below for screw locations, screw quantity and torque settings. The number listed
in the "#" column corresponds to the location on the fixture. See the fixture diagram and number on
the next page for SCREW LOCATION depictions.
#
1 Lens Assembly to Head Casting (x6)
2 Lamp Cover to Head Casting (x4)
3 Yoke Arm Cover to Yoke Frame (8 x Each Side = 16 Total) 6.5-8.7 In-Lb
4 Access Cover to Yoke Frame (x4)
5 Handle to Base Casting (2 x Each Side = 4 Total)
6 Bottom Cover to Base Casting (x12)
7 Power & Data Connector to Base Casting (x10)
8 1/4 Turn Adaptor Plate to Bottom Cover (x16)
TORQUE DRIVERS (Recommended):
UTICA TS-30 (Shown)
ALTERNATIVE DRIVERS:
Proto J6107A
Wiha 28887
CAUTION! DO NOT OVER TORQUE SCREWS AS THIS CAN CAUSE LEAKAGE ISSUES!
TO CONFIRM THE IP65 INTENGRITY AFTER A LAMP REPLACEMENT, TEST THE FIXTURE
USING THE ELATION IP TESTER. CONTACT ELATION SERVICE FOR MORE DETAILS.
ADJ Products, LLC - www.adj.com - Hydro Wash X7 User Manual Page 11
SCREW LOCATIONS
Torque Settings & IP Tester
SCREW TORQUE SETTINGS
6.5-8.7 In-Lb
6.5-8.7 In-Lb
Fasten by Manual Screwdriver
Fasten by Air Screwdriver
6.7-9.6 In-Lb
6.5-8.7 In-Lb
6.5-8.7 In-Lb

Advertisement

Table of Contents
loading

Table of Contents