SECTION 3: CONFIGURATION

Display Mode

The 800 Series changer is equipped with a
four-digit, seven-segment display, located on
the acceptor gate. The Display Mode is utilized
via the four Inventory Buttons also located on
the acceptor gate (see Figure 9).
This Display Mode is used to read information
as well as to set different options including
price settings and tube float levels.
The Display Mode may be entered by pressing
Inventory Buttons A and D simultaneously. In
response, the display will turn on the message
"FILL", "FULL", or "AbCd". Button activa-
tion will be recognized only if longer than 0.5
seconds. Once you have entered the Display
Mode, Inventory Buttons A through D are used
to move through the addresses as follows:
A .......................................... ESCAPE
But t o n
Button B...................................... INCREASE
Button C ............................................. ENTER
Button D .................................... DECREASE
EXAMPLE: Simultaneously press A and D to
enter Display Mode. Press B to increase
(scroll) through the various addresses. Once
you have reached the address you need to
access, press Button C to enter the address.
Information currently stored in non-volatile
memory will be displayed with the far right
decimal point illuminated. Use either Inventory
Buttons B or D to increase or decrease the
address values as needed. Press Button C again
to store the selection. Press A to return to the
Address Display. Press A again to exit the
Display Mode.
You will exit the Display Mode if one of the
following procedures is performed:
1. No Inventory Buttons are pressed or coins
are dropped for more than 45 seconds;
2. Depressing the A Button until the Display
Mode is exited;
3. Automatic exit after hardware reset.
800 Series
A B C D
800 Series Changer
DIGITAL DISPLAY
Figure 9
DIGITAL DISPLAY
(Normal Operating State)
8 8 8 8
Indicates At Least One Coin Is Enabled
Indicates (By A Flash) Each
Changer/Acceptor Communication
Figure 10
NOTE: All addresses in the Display Mode can
be made "Read Only" (disabled) via Coinco
Support Software (see separate Coinco Support
software manual for further information).
NOTE: If power is removed from the changer
before the Display Mode is exited, the changes
may not be saved.
Digital Display
Inventory Buttons
Indicates Power
is ON
Indicates Float Level Is Set On
At Least One Tube