Table of Contents Section 1: General Information Introduction ........................3 After Unpacking ......................... 3 Model Explanations ......................3 Features ..........................3 Main Logic Board Assembly ....................4 Specifications ........................4 Section 2: Installation Installing the Changer ......................5 Vend Price and Option Switch Setting ................5 Section 3: Operation Coin Recognition ........................
Section 1: General Information MAIN LOGIC BOARD ASSEMBLY SPECIFICATIONS Power Requirements Vend Price Range Operating Temperature Storage Temperature Physical Dimensions Physical Weight in Shipping Carton Coin Tube Capacity $.05 $.10 $.25 Tube Tube Tube LO $.25 LO $.25 Option Switch Option Switch Set to OFF Set to ON Position...
Section 3: Operation ESCROW UNTIL VEND CHANGER VENDOR INTERFACE See figure 9 and 10 9300 SERIES CHANGER JONES PLUG PIN CONNECTION Changer Jones Plug PIN # FUNCTION VAC (HOT) VAC (NEUTRAL) VEND RELAY-NORMALLY OPEN NC (NO CONNECTION) EXACT CHANGE-NORMALLY OPEN (NUETRAL) ACCEPT COINS (HOT) VEND RELAY-NORMALLY CLOSED (HOT) NC (NO CONNECTION)
Section 4: Maintenance ROUTINE MAINTENANCE Payout Assembly CLEANING REMOVING/REPLACING INDIVIDUAL MODULE ASSEMBLIES CAUTION: Never submerge changer in water. Do not use petroleum solvents, steel wool, scouring pads, or a metal brush for cleaning. Do not spray any part of changer with any type of lubricant.
Section 4: Maintenance DISASSEMBLING PAYOUT BASE FOR CLEANING DO NOT SUBMERGE TRANSFORMER OR SOLENOIDS IN WATER. Figure 12 CLEARING COIN JAMS CAUTION: Excessive screwdriver pressure or twisting can cause permanent damage to the coin changer. Figure 13...
Section 5: Troubleshooting INTRODUCTION NOTE: The following Troubleshooting Guide is based on the fact that the tester or vendor, with which the defective changer is being tested, functions properly when used with a known good changer. 9300-S TROUBLESHOOTING GUIDE TROUBLE POSSIBLE CAUSE PROCEDURE REMEDY...
Page 16
Section 5: Troubleshooting 9300-S TROUBLESHOOTING GUIDE TROUBLE POSSIBLE CAUSE PROCEDURE REMEDY No coin acceptance Coin return lever Make sure changer is mounted Reposition changer solenoids engergize correctly and coin return lever and/or vendor when inventory switches is in proper position coin return lever.
Page 17
Section 5: Troubleshooting 9302-GX TROUBLESHOOTING GUIDE TROUBLE POSSIBLE CAUSE PROCEDURE REMEDY Exact change light does Open circuit Check continuity between pin 5 of Replace main logic board not flash for an over changer 8 pin Jones plug & P3 insertion when correct pin 1, if open change is not available If harness is not open...
Need help?
Do you have a question about the 9300-S Series and is the answer not in the manual?
Questions and answers