Setting The Float Mode Levels; Activating Float Pay-Down - Coinco 800 Series Operation And Service Manual

Table of Contents

Advertisement

SECTION 3: CONFIGURATION
Setting The Float Mode
Levels
The Float Mode Levels for both Float Level and
Float Pay-down can be set in two ways:
• via Coinco Support Software;
• via the Digital Display.
VIA COINCO SUPPORT SOFTWARE
Consult Coinco Support Software manual for
tube float level setting instructions.
VIA DIGITAL DISPLAY
The Digital Display/Inventory Buttons are
located on the acceptor gate. Address "A007"
allows you to clear all float levels and to set all
four float levels at one time. The individual tube
float levels are set using Address "A008".
Setting All Four Float Levels At Once:
1. Load the four coin tubes to the float level
you want the coin changer to maintain.
2. Enter the Display Mode (see "Display
Mode" section of this manual).
3. Press B to scroll up to Address "A007"
4. Press C to enter Address "A007". The
display will show the current float mode
settings for all tubes. The far left digit
represents tube A through the far right digit
representing tube D.
5. Press B (increase) or D (decrease) to "1" to
set standard float levels, "2" for float pay-
down, or "0" to disable float mode.
6. Press C to enter your selection. The far right
decimal point will illuminate indicated the
selection has been stored.
7. Press A to return to the Address selection.
8. Press A again to exit display mode. All four
tube float levels are now set.
The Digital Display's second decimal point
from the right will be illuminated if any tube
float levels have been set.
800 Series
Setting Float Levels Individually:
1. Load the individual coin tube to the float
level you want the coin changer to maintain.
2. Enter the Display Mode (see "Display
Mode" section of this manual).
3. Press B to scroll up to Address "A008" for
individual tube float setting.
4. Press C to enter the Address.
5. "A" will be displayed indicating tube "A".
Use button B (increase) or button D (de-
crease) to reach the desired tube selection.
6. Press C to enter the Sub Address.
7. Use button B (increase) to reach the correct
setting ("0" to disable, "1" for standard float,
"2" for float pay-down).
8. Press C to store setting. The far right deci-
mal point will illuminate indicating the
selection has been stored.
9. Press C again to return to the Sub Address
Display.
10.Press A to return to the Address Display.
11.Press A again to exit the Display Mode. The
tube float level is now set for the individual
tube you have chosen.
The Digital Display's second decimal from the
right will be illuminated if any tube float levels
have been set.

Activating Float Pay-Down

Pressing and releasing buttons A and B simulta-
neously activates Float Pay-down. Use Manual
Fill to replenish low tubes (see "Manual Fill
Mode" section of this manual).
Page 15

Advertisement

Table of Contents
loading

This manual is also suitable for:

Global2

Table of Contents