SECTION 3: CONFIGURATION
Setting The Vend Price
on MDB & BDV
Changers
Vend prices for MDB/BDV changers are set
through the vending machine controller (VMC).
See vending machine manual for details.

Manual Fill Mode

Manual Fill Mode allows coins to be inserted
into the acceptor which routes the coins to the
proper coin tube without establishing credit.
When high sensor level or float level is reached
and in manual fill mode, coins will be rejected.
Enter the Display Mode (see "Display Mode"
section of this manual). When "FILL" appears
in the display, deposit coins until the desired
level. Alternating with the "FILL" message will
be the tubes needing coins "AbCd". The
changer will automatically return to operating
mode after 45 seconds of no activity or if button
A (escape) is pressed.
Manual Fill Mode is supported for
Single-/Four-Price, Protocol A, and BDV
changers. Manual Fill Mode in MDB changers
is accessed through the vending machine con-
troller. See vending machine manual for details.
Page 14

Float Mode

Float Mode is used to systematically reduce the
number of coins kept in a tube.
The 800 Series GLOBAL2
two Float Mode Options which are set through
the use of Coinco Support Software or the
digital display.
STANDARD LEVEL FLOAT MODE
In Standard Float Level Mode, once a tube float
level is set (see "Setting The Float Mode Lev-
els" section), the changer will try to maintain
the set level of coins in the tube by routing
accepted coins to the tube only if a coin was
paid out. Once the tube reaches its float level in
Standard Float Mode, any coins normally routed
to that tube will be sent to the cashbox. As
usual, any cashbox coins will be accepted and
routed to the cashbox.
FLOAT PAY-DOWN MODE
In Float Pay-down Mode, the acceptor will
continue to route coins to the tube until the
upper sensor is covered. The coins will then be
routed to the cashbox. Once a tube float level is
set, activating Float Pay-down will dispense
coins above the established levels until the coins
reach the float levels (see "Activating Float
Pay-down" section of this manual).
When in Manual Fill Mode, the acceptor will
route coins to the tube until float level is
reached. When float level is reached the display
will change to "FULL" and coins will be re-
jected. The float pay-down level does not
change. The changer will automatically return
to operating mode after 45 seconds of no activ-
ity or if button A (escape) is pressed.
®