SECTION 3: CONFIGURATION
Setting The "Use Correct
Change" Value
Single-/Four-Price and Protocol A Models Only
When a value is selected for turning on the "Use
Correct Change" light, the light is illuminated
when the changer is unable to make change for
THAT value or any lesser value.
NOTE: Option switch D set to the ON position
will override any setting you make via the
following instructions. See "Option Switch
Module" section of this manual for information
on Option Switch D.
The "Use Correct Change" light can be pro-
grammed to come on in three ways:
• via Coinco Support Software;
• via DEX/UCS (Protocol A Only);
• via the Digital Display.
VIA COINCO SUPPORT SOFTWARE
Consult Coinco Support Software manual for
"Use Correct Change" light setting instructions.
VIA DEX/UCS
Consult Hand-held Computer manufacturer.
VIA DIGITAL DISPLAY
The "Use Correct Change" light is set using
Address "C032" of the Digital Display.
1. Enter the Display Mode (see "Display
Mode" section of this manual).
2. Press B to scroll up to Address "C032"
("Use Correct Change" Setting).
3. Press C to enter the Address.
4. Use button B (increase) or button D
(decrease) to reach the correct value.
5. Press C to store setting.
6. Press A to return to the Address Display.
7. Press A again to exit the Display Mode. The
Exact Change Setting is now programmed to
the value you have set.
Page 16
Setting The Exact Change
Accept Group
Single-/Four-Price and Protocol A Models Only
By setting the Exact Change Group you are
telling the changer what coins to accept when
the "Use Correct Change" light is ON. When
the light is OFF, all enabled coins in the coin set
are accepted.
The Exact Change Group can be programmed in
three ways:
• via Coinco Support Software;
• via DEX/UCS;
• via the Digital Display.
VIA COINCO SUPPORT SOFTWARE
Consult Coinco Support Software manual for
"Use Correct Change" light setting instructions.
VIA DEX/UCS
Consult Hand-held Computer manufacturer.
VIA DIGITAL DISPLAY
The Exact Change Group is set using Address
"C014" of the Digital Display.
1. Enter the Display Mode (see "Display
Mode" section of this manual).
2. Press B to scroll up to Address "C014"
3. Press C to enter the Address.
4. Use button B (increase) or button D
(decrease) to reach the coin value or Exact
Change group to be accepted.
5. Press A to return to the Address Display.
6. Press A to exit the Display Mode. The Exact
Change coin value/group is now pro-
grammed to the value you have set.