7.3

Jog

Setting Jog
The Jog function, when selected will allow the motor to be manually rotated by a pre-
determined value with each press of
continuously until
To enable or disable the Jog function, the following actions should be performed:
Select Control
Note
Selection of Jog frequencies
It is important that the Jog parameters P1058 (Jog right) and P1059 (Jog left) are set to the
required frequencies for the users application. The default jogging setpoint for both
parameters is 5 Hz (150 rpm).
When the Jog left and Jog right (Jog1 and Jog 2) have been set; it is necessary to do a long
press of the "INFO" key to select the other jog mode.
7.4

Custom Hand mode

Overview
The custom hand mode allows the user to setup a command source and setpoint source
directly from the Intelligent Operator Panel 2 (IOP-2).
When the custom hand mode has been set, the IOP-2 Sensor Control Field can be used as the
setpoint source.
The Auto mode is unaffected by any changes made by the custom hand mode function.
A breakdown of all the interconnection inputs are given in the table below.
Intelligent Operating Panel 2 (IOP-2)
Operating Instructions, 06/2020, FW V2.6, A5E39549448B AH
. If
is released.
Select Jog
is pressed continuously, the motor will rotate
Select Off or On
Control menu
7.3 Jog
41