Setup Menu
6.1 Example Setups
Dynamic Drive Control
• Dynamic Drive Control is preset for the Power Modules PM240, PM240-2 and PM330 in
frame sizes ≥ FSD. This application class can, for example, be used for the following
applications:
– Pumps and compressors with displacement machine
– Rotary furnaces
– Extruders
– Centrifuges
Expert
• Expert is fixed assigned to the Power Modules PM230, PM250 and PM260 as soon as for
G120D, G110M and ET200pro FC-2. This setting corresponds to the existing Setup and
will also be assigned to existing projects. It allows the flexibly setup of the converter, but
requires a detailed understanding of the drive.
Motor data identification (motor ID)
When selecting motor data identification (motor ID) with subsequent ramp-up to the
setpoint speed (p1900 = 11 or 12; 12 = standard setting based on SINAMICS Firmware V4.7
SP3 with "Standard Drive Control" and "Dynamic Drive Control"), the motor is, upon the first
Power ON command, directly accelerated to the setpoint speed, following a short delay time
caused by the motor ID (approx. 15 to 30 s). From SINAMICS Firmware V4.7 SP6 the default
setting for p1900 = 2.
Note
Macro source selection
During the Quick Startup process, the user will be presented with a list of preset macros that
determine the configuration of the converter. Every Control Unit Operating Instructions
contain a list of the macros that are specific for that particular Control Unit and show the
wiring configurations for each macro. For further information, see the relevant Operating
Instructions.
30
WARNING
Intelligent Operating Panel 2 (IOP-2)
Operating Instructions, 06/2020, FW V2.6, A5E39549448B AH