Operating Requirements - ABB IRB 1200 Product Specification

Hide thumbs Also See for IRB 1200:
Table of Contents

Advertisement

1 Description

1.3.2 Operating requirements

1.3.2 Operating requirements
Protection standard
Robot variant
All variants, manipulator
Option, all variants
Explosive environments
The robot must not be located or operated in an explosive environment.
Working range limitations
EPS will not be selectable. No mechanical limitation.
Ambient temperature
Description
Manipulator during opera-
tion
Manipulator with food
grade lubrication during
operation
For the controller
Complete robot during
transportation and storage
For short periods (not ex-
ceeding 24 hours)
i
ii
Relative humidity
Description
Complete robot during operation, transportation and
storage
20
Protection class
Standard
Option
Standard/Option
Standard
Standard
At low environmental temperature < 10ºC is, as with any other machine, a warm-up phase
recommended to be run with the robot. Otherwise there is a risk that the robot stops or run with
lower performance due to temperature dependent oil and grease viscosity.
For robots with food grade lubrication, if environment temperature > 35ºC, contact ABB for further
information.
© Copyright 2021 ABB. All rights reserved.
Protection standard IEC529
IP40
IP67
Temperature
i
+ 5°C
(41°F) to + 45°C (113°F)
i
+ 5°C
(41°F) to + 35°C
(113°F)
See Product specification - Control-
ler IRC5
- 25°C (-13°F) to + 55°C (131°F)
up to + 70°C (158°F)
Relative humidity
Max. 95% at constant temperature