4.6.10 Frost protection temperature
Set temperature for frost protection mode.
1
Press
to enter menu.
4.6.11 Control algorithm
Set control algorithm: ITLC for radiators, SPAN (hysteresis) 0,5°C or SPAN (hysteresis) 0,25°C.
ITLC is a self-learning, time-proportional control algorithm. The regulation of the ITLC type ensures economical operation system due to more precise
temperature maintenance during the controlling process In addition to an accurate and stable room temperature, the advantage of this system is the
minimization of energy consumption and significant savings.
Hysteresis is the temperature difference between which the thermostat works, keeping the set temperature. For example, if you set the temperature to
20°C and if the hysteresis is ± 0.5°C, the heating will be turned on when the room temperature drops to 19.5°C and turned off when the temperature
reaches 20.5°C.
1
Press
to enter menu.
4
Using
or
control algorithm and then press
20
2
Using
parameters. Enter by
2
Using
parameters. Enter by
, choose
.
or
move between
button.
or
move between
button.
3
Using
or
, choose
frost protection temperature value
and then press
.
3
Using
or
, choose
parameter and then press
.