ADF Web HD67604-A1 User Manual

Profinet / profibus master - converter

Advertisement

Quick Links

Industrial Electronic Devices
User Manual
Revision 1.001
English
PROFINET / PROFIBUS Master - Converter
(Order Code: HD67604-A1)
for Website information:
www.adfweb.com/?Product=HD67604
for Price information:
www.adfweb.com/?Price=HD67604-A1
Benefits and Main Features:
Very easy to configure
PROFIBUS up to 6Mbps
Two PROFINET ports
Industrial temperature range:
-40°C / +85°C (-40°F / +185°F)
ADFweb.com Srl – IT31010 – Mareno – Treviso
User Manual PROFINET / PROFIBUS Master - Converter
Document code: MN67604_ENG
For others PROFIBUS devices, see also the following links:
PROFIBUS Master from/to ...
www.adfweb.com?Product=HD67570
www.adfweb.com?Product=HD67575
www.adfweb.com?Product=HD67577
www.adfweb.com?Product=HD67579
www.adfweb.com?Product=HD67580
EtherNet/IP from/to ...
www.adfweb.com?Product=HD67077
www.adfweb.com?Product=HD67589
www.adfweb.com?Product=HD67590
www.adfweb.com?Product=HD67591
www.adfweb.com?Product=HD67592
www.adfweb.com?Product=HD67593
www.adfweb.com?Product=HD67594
www.adfweb.com?Product=HD67595
www.adfweb.com?Product=HD67597
www.adfweb.com?Product=HD67598
Do you have an your customer protocol?
See the following links:
www.adfweb.com?Product=HD67003
Do you need to choose a device? do you want help?
Ask it to the following link:
www.adfweb.com?Cmd=helpme
Revision 1.001
Page 1 of 33
(... DeviceNet Slave)
(... Ethernet)
(... CAN)
(... Modbus TCP Slave)
(... Modbus Slave)
(... M-Bus)
(... NMEA 2000)
(... Serial)
(... Modbus Master)
(... Modbus Slave)
(... PROFIBUS Master)
(... PROFIBUS Slave)
(... CAN)
(... DeviceNet Master)
(... DeviceNet Slave)

Advertisement

Table of Contents
loading

Summary of Contents for ADF Web HD67604-A1

  • Page 1 Page 1 of 33 Industrial Electronic Devices User Manual Revision 1.001 English PROFINET / PROFIBUS Master - Converter (Order Code: HD67604-A1) for Website information: www.adfweb.com/?Product=HD67604 for Price information: For others PROFIBUS devices, see also the following links: www.adfweb.com/?Price=HD67604-A1 PROFIBUS Master from/to …...
  • Page 2: Table Of Contents

    User Manual PROFINET / PROFIBUS Master - Converter Document code: MN67604_ENG Revision 1.001 Page 2 of 33 Industrial Electronic Devices INDEX: UPDATED DOCUMENTATION: Dear customer, we thank you for your attention and we remind you that Page you need to check that the following document is: INDEX UPDATED DOCUMENTATION Updated;...
  • Page 3: Security Alert

    User Manual PROFINET / PROFIBUS Master - Converter Document code: MN67604_ENG Revision 1.001 Page 3 of 33 Industrial Electronic Devices SECURITY ALERT: ENERAL NFORMATION To ensure safe operation, the device must be operated according to the instructions in the manual. When using the device are required for each individual application, legal and safety regulation.
  • Page 4: Example Of Connection

    User Manual PROFINET / PROFIBUS Master - Converter Document code: MN67604_ENG Revision 1.001 Page 4 of 33 Industrial Electronic Devices EXAMPLE OF CONNECTION: Used with only one PROFINET connection. Used like switch, it allows to connect a second device to the network, without using an external switch; or to connect the device to an Access Point for connect them to a Wireless network (also internet).
  • Page 5: Connection Scheme

    User Manual PROFINET / PROFIBUS Master - Converter Document code: MN67604_ENG Revision 1.001 Page 5 of 33 Industrial Electronic Devices CONNECTION SCHEME: Figure 1: Connection scheme for HD67604-A1 ADFweb.com Srl – IT31010 – Mareno – Treviso...
  • Page 6: Characteristics

    User Manual PROFINET / PROFIBUS Master - Converter Document code: MN67604_ENG Revision 1.001 Page 6 of 33 Industrial Electronic Devices CHARACTERISTICS: The configurable “PROFINET / PROFIBUS Master - Converter” allows the following characteristics: Triple isolation between PROFINET/PROFIBUS, PROFINET/Power Supply, PROFIBUS/Power Supply. Mountable on 35mm Rail DIN;...
  • Page 7: Power Supply

    POWER SUPPLY: The devices can be powered between a wide range of tensions. For more details see the two tables below. Vmin Vmax Vmin Vmax HD67604-A1 Consumption at 24V DC: Device W/VA HD67604-A1 Caution: Not reverse the polarity power HD67604-A1...
  • Page 8: Function Modes

    User Manual PROFINET / PROFIBUS Master - Converter Document code: MN67604_ENG Revision 1.001 Page 8 of 33 Industrial Electronic Devices FUNCTION MODES: The device has got two functions mode depending of the position of the Dip2 of ‘Dip-Switch A’: The first, with Dip2 in Off position (factory setting), is used for the normal working of the device. The second, with Dip2 in On position, is used for upload the Project/Firmware.
  • Page 9: Leds

    User Manual PROFINET / PROFIBUS Master - Converter Document code: MN67604_ENG Revision 1.001 Page 9 of 33 Industrial Electronic Devices LEDS: The device has got six LEDs that are used to give information of the functioning status. The various meanings of the LEDs are described in the table below. Normal Mode Boot Mode ON: Device powered...
  • Page 10: Profibus

    PROFINET: The PROFINET connection must be made using Connector3 and/or Connector4 of HD67604-A1 with at least a Category 5E cable. The maximum length of the cable should not exceed 100m. The cable has to conform to the T568 norms relative to connections in cat.5 up to 100 Mbps.
  • Page 11: Usb

    User Manual PROFINET / PROFIBUS Master - Converter Document code: MN67604_ENG Revision 1.001 Page 11 of 33 Industrial Electronic Devices USB: The USB connection, must be made with a USB cable with a USB Mini B plug. Note: The USB port is not used in this moment. ADFweb.com Srl –...
  • Page 12: Use Of Configurator Sw67604

    User Manual PROFINET / PROFIBUS Master - Converter Document code: MN67604_ENG Revision 1.001 Page 12 of 33 Industrial Electronic Devices USE OF CONFIGURATOR SW67604: To configure the Converter, use the available software that runs with Windows, called SW67604. It is downloadable on the site www.adfweb.com and its operation is described in this document.
  • Page 13: New Configuration / Open Configuration

    User Manual PROFINET / PROFIBUS Master - Converter Document code: MN67604_ENG Revision 1.001 Page 13 of 33 Industrial Electronic Devices NEW CONFIGURATION / OPEN CONFIGURATION: “New Configuration” button creates the folder which contains the entire device configuration. A device configuration can also be imported or exported: To clone the configurations of a programmable “PROFINET / PROFIBUS Master - Converter”...
  • Page 14: Set Communication

    User Manual PROFINET / PROFIBUS Master - Converter Document code: MN67604_ENG Revision 1.001 Page 14 of 33 Industrial Electronic Devices SET COMMUNICATION: This section defines the fundamental communication parameter of two buses, PROFIBUS and PROFINET. By pressing the “Set Communication” button from the main window for SW67604 (Fig. 2) the window “SET COMMUNICATION”...
  • Page 15: Profibus Network

    User Manual PROFINET / PROFIBUS Master - Converter Document code: MN67604_ENG Revision 1.001 Page 15 of 33 Industrial Electronic Devices PROFIBUS NETWORK: By pressing the “PROFIBUS Network” button from the main window for SW67604 (Fig. 2) the window “PROFIBUS Network Management” (Fig.
  • Page 16: Master Profibus Options

    User Manual PROFINET / PROFIBUS Master - Converter Document code: MN67604_ENG Revision 1.001 Page 16 of 33 Industrial Electronic Devices MASTER PROFIBUS OPTIONS: By pressing the “Master PROFIBUS Options” button from the “PROFIBUS Network” window (Fig. 4) the “PROFIBUS Master Options” window appears (Fig.
  • Page 17: Profibus Device

    User Manual PROFINET / PROFIBUS Master - Converter Document code: MN67604_ENG Revision 1.001 Page 17 of 33 Industrial Electronic Devices PROFIBUS DEVICE: By pressing the “Add Slave PROFIBUS” and “Modify Slave PROFIBUS” button (or double click above an existent PROFIBUS Slave) from the “PROFIBUS Network”...
  • Page 18: Module Selection

    User Manual PROFINET / PROFIBUS Master - Converter Document code: MN67604_ENG Revision 1.001 Page 18 of 33 Industrial Electronic Devices ODULE ELECTION The section “Module Selection” is used to select which Modules are present in the Slave (Fig. 7). In this section is possible to: Check the list of the Modules selected...
  • Page 19 User Manual PROFINET / PROFIBUS Master - Converter Document code: MN67604_ENG Revision 1.001 Page 19 of 33 Industrial Electronic Devices By pressing the “Manual Module” button from the “PROFIBUS Device” window (Fig. 6) the “Add Module Manually” window appears (Fig. 8). In this window is possible to add a Module manually, i.e.
  • Page 20: User Parameters

    User Manual PROFINET / PROFIBUS Master - Converter Document code: MN67604_ENG Revision 1.001 Page 20 of 33 Industrial Electronic Devices ARAMETERS The section “User Parameters” is used to modify the parameters of the PROFIBUS slave (Fig. 9). In this section there are: The List of all Parameters available for the PROFIBUS device (“User Parameters”) (Fig.
  • Page 21 User Manual PROFINET / PROFIBUS Master - Converter Document code: MN67604_ENG Revision 1.001 Page 21 of 33 Industrial Electronic Devices By pressing the “Modify User Parameters Manually” button from the “PROFIBUS Device” window (Fig. 6) the “Add Module Manually” window appears (Fig. 10). In this window is possible to add/modify the User and/or Modules Parameters manually, i.e.
  • Page 22: Module Parameters

    User Manual PROFINET / PROFIBUS Master - Converter Document code: MN67604_ENG Revision 1.001 Page 22 of 33 Industrial Electronic Devices ODULE ARAMETERS The section “Module Parameters” is used to modify the parameters of the Modules (Fig. 11). In this section there are: The List of all Module selected in the GSD file (“Available modules”) (Fig.
  • Page 23: Capabilities

    User Manual PROFINET / PROFIBUS Master - Converter Document code: MN67604_ENG Revision 1.001 Page 23 of 33 Industrial Electronic Devices APABILITIES The section “Capabilities” is used only to show which features/baudrates available in the PROFIBUS device. The Green Icon indicate that capability/baudrate is available, the Red Icon indicate no compatibilities with that capability/baudrate (Fig.
  • Page 24: Options

    User Manual PROFINET / PROFIBUS Master - Converter Document code: MN67604_ENG Revision 1.001 Page 24 of 33 Industrial Electronic Devices PTIONS The section “Options” is used to enable some option for each PROFIBUS device (Fig. 13). The means of the fields are: field “Enable Sync”...
  • Page 25: Update Device

    User Manual PROFINET / PROFIBUS Master - Converter Document code: MN67604_ENG Revision 1.001 Page 25 of 33 Industrial Electronic Devices UPDATE DEVICE: By pressing the “Update Converter” button it is possible to load the created Configuration into the device; and also the Firmware, if is necessary.
  • Page 26 At this point the configuration/firmware on the device is correctly update. Note: When you install a new version of the software it is better if the first time you do the update of the Firmware in the HD67604-A1 device. Note: When you receive the device, for the first time, you have to update also the Firmware in the HD67604-A1 device.
  • Page 27: Mechanical Dimensions

    User Manual PROFINET / PROFIBUS Master - Converter Document code: MN67604_ENG Revision 1.001 Page 27 of 33 Industrial Electronic Devices MECHANICAL DIMENSIONS: Figure 16: Mechanical dimensions scheme for HD67604-A1 ADFweb.com Srl – IT31010 – Mareno – Treviso...
  • Page 28: Order Code

    User Manual PROFINET / PROFIBUS Master - Converter Document code: MN67604_ENG Revision 1.001 Page 28 of 33 Industrial Electronic Devices ORDERING INFORMATIONS: The ordering part number is formed by a valid combination of the following: HD67604 – A 1 Connectors Type 1: Removable 5mm Screw Terminal Enclosure Type A: 1M, 35mm DIN Rail mounting...
  • Page 29: Plc Configuration

    User Manual PROFINET / PROFIBUS Master - Converter Document code: MN67604_ENG Revision 1.001 Page 29 of 33 Industrial Electronic Devices PLC CONFIGURATION: The configuration and commissioning of the PROFINET Converter as described on the following pages was accomplished with the help of the TIA Portal V11-software of Siemens.
  • Page 30 User Manual PROFINET / PROFIBUS Master - Converter Document code: MN67604_ENG Revision 1.001 Page 30 of 33 Industrial Electronic Devices 2) Import the module in the network; connect the device to the PLC network and edit the parameters of IP, station name etc. ADFweb.com Srl –...
  • Page 31 User Manual PROFINET / PROFIBUS Master - Converter Document code: MN67604_ENG Revision 1.001 Page 31 of 33 Industrial Electronic Devices 3) Load the configuration into the PLC. ADFweb.com Srl – IT31010 – Mareno – Treviso...
  • Page 32: Disclaimer

    User Manual PROFINET / PROFIBUS Master - Converter Document code: MN67604_ENG Revision 1.001 Page 32 of 33 Industrial Electronic Devices DISCLAIMER All technical content within this document can be modified without notice. The content of the document content is a recurring audit. For losses due to fire, earthquake, third party access or other accidents, or intentional or accidental abuse, misuse, or use under abnormal conditions repairs are charged to the user.
  • Page 33: Warranties And Technical Support

    User Manual PROFINET / PROFIBUS Master - Converter Document code: MN67604_ENG Revision 1.001 Page 33 of 33 Industrial Electronic Devices WARRANTIES AND TECHNICAL SUPPORT: For fast and easy technical support for your ADFweb.com SRL products, consult our internet support at www.adfweb.com. Otherwise contact us at the address support@adfweb.com RETURN POLICY: If while using your product you have any problem and you wish to exchange or repair it, please do the following:...

Table of Contents