Download Print this page
ADF Web HD67608-A1 User Manual

ADF Web HD67608-A1 User Manual

Profinet / devicenet master - converter
Hide thumbs Also See for HD67608-A1:

Advertisement

Quick Links

Industrial Electronic Devices
User Manual
Revision 1.001
English
PROFINET / DeviceNet Master - Converter
(Order Code: HD67608-A1)
For Website information:
www.adfweb.com?Product=HD67608
For Price information:
www.adfweb.com?Price=HD67608-A1
Benefits and Main Features:
Electrical isolation
Two PROFINET ports
Temperature range: -40°C / +85°C (-40°F / +185°F)
User manual
ADFweb.com Srl – IT31010 – Mareno – Treviso
User Manual PROFINET / DeviceNet Master
Document code: MN67608_ENG
For other PROFINET products see also the following link:
Converter PROFINET to
www.adfweb.com?Product=HD67078
www.adfweb.com?Product=HD67090
www.adfweb.com?Product=HD67178
www.adfweb.com?Product=HD67600
www.adfweb.com?Product=HD67601
www.adfweb.com?Product=HD67602
www.adfweb.com?Product=HD67603
www.adfweb.com?Product=HD67604
www.adfweb.com?Product=HD67605
www.adfweb.com?Product=HD67606
www.adfweb.com?Product=HD67607
www.adfweb.com?Product=HD67609
www.adfweb.com?Product=HD67610
www.adfweb.com?Product=HD67612
www.adfweb.com?Product=HD67613
www.adfweb.com?Product=HD67614
www.adfweb.com?Product=HD67615
www.adfweb.com?Product=HD67633
www.adfweb.com?Product=HD67659
www.adfweb.com?Product=HD67660
www.adfweb.com?Product=HD67661
www.adfweb.com?Product=HD67679
www.adfweb.com?Product=HD67719
www.adfweb.com?Product=HD67752
www.adfweb.com?Product=HD67778
www.adfweb.com?Product=HD67818
www.adfweb.com?Product=HD67848
www.adfweb.com?Product=HD67876
www.adfweb.com?Product=HD67912
www.adfweb.com?Product=HD67952
www.adfweb.com?Product=HD67984
www.adfweb.com?Product=HD67B22
www.adfweb.com?Product=HD67B46
www.adfweb.com?Product=HD67C77
www.adfweb.com?Product=HD67D33
www.adfweb.com?Product=HD67E23
www.adfweb.com?Product=HD67E73
www.adfweb.com?Product=HD67F33
INFO:
www.adfweb.com
Revision 1.001
Pagina 1 di 28
(M-bus)
(M-bus Wireless)
(SNMP Manager)
(NMEA 2000)
(Serial)
(Modbus Master)
(Modbus Slave)
(PROFIBUS Master)
(PROFIBUS Slave)
(CAN)
(CANopen)
(DeviceNet Slave)
(J1939)
(Modbus TCP Slave)
(SNMP Agent)
(DMX)
(NMEA 0183)
(S7comm)
(EtherNet)
(EtherNet/IP Slave)
(EtherNet/IP Master)
(BACnet Slave)
(BACnet Master)
(IEC 61850 Server)
(IEC 61850 Client)
(KNX)
(DALI)
(IO-Link Master)
(HART)
(MQTT)
(IO-Link Slave)
(OPC UA Client)
(OPC UA Server)
(EnOcean)
(LoRaWAN)
(EtherCAT Slave)
(EtherCAT Master)
(LoRaWAN Gateway)
Phone +39.0438.30.91.31

Advertisement

loading
Need help?

Need help?

Do you have a question about the HD67608-A1 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ADF Web HD67608-A1

  • Page 1 For other PROFINET products see also the following link: English Converter PROFINET to www.adfweb.com?Product=HD67078 (M-bus) www.adfweb.com?Product=HD67090 (M-bus Wireless) PROFINET / DeviceNet Master - Converter www.adfweb.com?Product=HD67178 (SNMP Manager) (Order Code: HD67608-A1) www.adfweb.com?Product=HD67600 (NMEA 2000) www.adfweb.com?Product=HD67601 (Serial) www.adfweb.com?Product=HD67602 (Modbus Master) For Website information: www.adfweb.com?Product=HD67603 (Modbus Slave) www.adfweb.com?Product=HD67608...
  • Page 2: Updated Documentation

    User Manual PROFINET / DeviceNet Master Document code: MN67608_ENG Revision 1.001 Pagina 2 di 28 Industrial Electronic Devices INDEX: UPDATED DOCUMENTATION: Dear customer, we thank you for your attention and we remind you that Page you need to check that the following document is: INDEX Updated UPDATED DOCUMENTATION...
  • Page 3: Security Alert

    User Manual PROFINET / DeviceNet Master Document code: MN67608_ENG Revision 1.001 Pagina 3 di 28 Industrial Electronic Devices SECURITY ALERT: ENERAL NFORMATION To ensure safe operation, the device must be operated according to the instructions in the manual. When using the device are required for each individual application, legal and safety regulation.
  • Page 4: Example Of Connection

    User Manual PROFINET / DeviceNet Master Document code: MN67608_ENG Revision 1.001 Pagina 4 di 28 Industrial Electronic Devices EXAMPLE OF CONNECTION: ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 5: Connection Scheme

    User Manual PROFINET / DeviceNet Master Document code: MN67608_ENG Revision 1.001 Pagina 5 di 28 Industrial Electronic Devices CONNECTION SCHEME: Figure 1: Connection scheme for HD67608-A1 ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 6 Pagina 6 di 28 Industrial Electronic Devices CHARACTERISTICS: The HD67608-A1 is a PROFINET / DeviceNet Master - Converter. It allows the following characteristics: Up to 1439 bytes in reading and 1439 bytes in writing; Triple isolation between DeviceNet - Power Supply, DeviceNet - Ethernet, Power Supply - Ethernet.
  • Page 7: Power Supply

    The devices can be powered at 8…24V AC and 12…35V DC. For more details see the two tables below. Vmin Vmax Vmin Vmax Consumption at 24V DC: Device Consumption [W/VA] HD67608-A1 Caution: Not reverse the polarity power HD67608-A1 ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 8: Function Modes

    User Manual PROFINET / DeviceNet Master Document code: MN67608_ENG Revision 1.001 Pagina 8 di 28 Industrial Electronic Devices FUNCTION MODES: The device has got two functions mode depending of the position of the Dip1 of ‘Dip-Switch A’: The first, with Dip1 in Off position (factory setting), is used for the normal working of the device. The second, with Dip1 in On position, is used for upload the Project/Firmware.
  • Page 9 User Manual PROFINET / DeviceNet Master Document code: MN67608_ENG Revision 1.001 Pagina 9 di 28 Industrial Electronic Devices LEDS: The device has got six LEDs that are used to give information of the functioning status. The various meanings of the LEDs are described in the table below. Normal Mode Boot Mode ON: Device powered...
  • Page 10 PROFINET: The PROFINET connection must be made using Connector3 and/or Connector4 of HD67608-A1 with at least a Category 5E cable. The maximum length of the cable should not exceed 100m. The cable has to conform to the T568 norms relative to connections in cat.5 up to 100 Mbps.
  • Page 11 User Manual PROFINET / DeviceNet Master Document code: MN67608_ENG Revision 1.001 Pagina 11 di 28 Industrial Electronic Devices DeviceNet: For terminate the DeviceNet line with a 120Ω resistor it is necessary that the Dip1 of ‘Dip-Switch A’ is at ON position. Cable characteristics: DC parameter: Impedance...
  • Page 12 User Manual PROFINET / DeviceNet Master Document code: MN67608_ENG Revision 1.001 Pagina 12 di 28 Industrial Electronic Devices USE OF COMPOSITOR SW67608: To configure the Converter, use the available software that runs with Windows called SW67608. It is downloadable on the site www.adfweb.com and its operation is described in this document.
  • Page 13: New Configuration / Open Configuration

    User Manual PROFINET / DeviceNet Master Document code: MN67608_ENG Revision 1.001 Pagina 13 di 28 Industrial Electronic Devices NEW CONFIGURATION / OPEN CONFIGURATION: “New Configuration” button creates the folder which contains the entire device’s configuration. A device’s configuration can also be imported or exported: To clone the configurations of a Programmable “PROFINET / DeviceNet Master - Converter”...
  • Page 14: Software Options

    User Manual PROFINET / DeviceNet Master Document code: MN67608_ENG Revision 1.001 Pagina 14 di 28 Industrial Electronic Devices SOFTWARE OPTIONS: By pressing the “Settings” ( ) button there is the possibility to change the language of the software and check the updatings for the compositor.
  • Page 15: Set Communication

    User Manual PROFINET / DeviceNet Master Document code: MN67608_ENG Revision 1.001 Pagina 15 di 28 Industrial Electronic Devices SET COMMUNICATION: This section define the fundamental communication parameters of two buses, PROFINET and DeviceNet Master. By Pressing the “Set Communication” button from the main window for SW67608 (Fig. 2) the window “Set Communication”...
  • Page 16: Devicenet Network

    User Manual PROFINET / DeviceNet Master Document code: MN67608_ENG Revision 1.001 Pagina 16 di 28 Industrial Electronic Devices DEVICENET NETWORK: By pressing the “DeviceNet Network” button from the main window for SW67608 (Fig. 2) the window “DeviceNet Network” appears (Fig. The data of the columns have the following meanings: In the field “ID”...
  • Page 17 User Manual PROFINET / DeviceNet Master Document code: MN67608_ENG Revision 1.001 Pagina 17 di 28 Industrial Electronic Devices DEFINE BYTE: By pressing the “Define Byte” button from the main window for SW67608 (Fig. 2) the window “Define Offset” appears (Fig. 5). In the field “Select the Slave DeviceNet”...
  • Page 18 User Manual PROFINET / DeviceNet Master Document code: MN67608_ENG Revision 1.001 Pagina 18 di 28 Industrial Electronic Devices XML FILE: By Pressing the “PROFINET XML” button from the main window for SW67608 (Fig. 2) it is possible to generate the xml file to be imported into the master PROFINET.
  • Page 19: Update Device

    User Manual PROFINET / DeviceNet Master Document code: MN67608_ENG Revision 1.001 Pagina 19 di 28 Industrial Electronic Devices UPDATE DEVICE: By pressing the “Update Device” button, it is possible to load the created Configuration into the device; and also the Firmware, if necessary. This by using the Ethernet port. If you don’t know the actual IP address of the device you have to use this procedure: Turn OFF the Device;...
  • Page 20 User Manual PROFINET / DeviceNet Master Document code: MN67608_ENG Revision 1.001 Pagina 20 di 28 Industrial Electronic Devices Note: When you receive the device, for the first time, you also have to update the Firmware in the HD67608 device. Warning: If Fig.
  • Page 21 User Manual PROFINET / DeviceNet Master Document code: MN67608_ENG Revision 1.001 Pagina 21 di 28 Industrial Electronic Devices MODBUS DIAGNOSTIC OVER PROFINET: During the normal functioning of the device, if all configured DeviceNet slaves are communicating, every PROFINET frame has the "Data Status"...
  • Page 22: Mechanical Dimensions

    User Manual PROFINET / DeviceNet Master Document code: MN67608_ENG Revision 1.001 Pagina 22 di 28 Industrial Electronic Devices MECHANICAL DIMENSIONS: Figure 8: Mechanical dimensions scheme for HD67608-A1 ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 23: Ordering Informations

    Enclosure Type A: 1M, 35mm DIN Rail mounting Device Family HD67608: PROFINET / DeviceNet Master - Converter Order Code: HD67608-A1 PROFINET / DeviceNet Master - Converter ACCESSORIES: Order Code: AC34011 35mm Rail DIN - Power Supply 220/240V AC 50/60Hz – 12 V DC Order Code: AC34012 35mm Rail DIN - Power Supply 220/240V AC 50/60Hz –...
  • Page 24: Plc Configuration

    User Manual PROFINET / DeviceNet Master Document code: MN67608_ENG Revision 1.001 Pagina 24 di 28 Industrial Electronic Devices PLC CONFIGURATION: The configuration and commissioning of the PROFINET Converter as described on the following pages was accomplished with the help of the TIA Portal V11-software of Siemens.
  • Page 25 User Manual PROFINET / DeviceNet Master Document code: MN67608_ENG Revision 1.001 Pagina 25 di 28 Industrial Electronic Devices 2) Import the module in the network; connect the device to the PLC network and edit the parameters of IP, station name etc. ADFweb.com Srl –...
  • Page 26 User Manual PROFINET / DeviceNet Master Document code: MN67608_ENG Revision 1.001 Pagina 26 di 28 Industrial Electronic Devices 3) Load the configuration into the PLC. ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 27: Other Regulations And Standards

    User Manual PROFINET / DeviceNet Master Document code: MN67608_ENG Revision 1.001 Pagina 27 di 28 Industrial Electronic Devices DISCLAIMER All technical content within this document can be modified without notice. The content of the document content is a recurring audit. For losses due to fire, earthquake, third party access or other accidents, or intentional or accidental abuse, misuse, or use under abnormal conditions repairs are charged to the user.
  • Page 28: Warranties And Technical Support

    User Manual PROFINET / DeviceNet Master Document code: MN67608_ENG Revision 1.001 Pagina 28 di 28 Industrial Electronic Devices WARRANTIES AND TECHNICAL SUPPORT: For fast and easy technical support for your ADFweb.com SRL products, consult our internet support at www.adfweb.com. Otherwise contact us at the address support@adfweb.com RETURN POLICY: If while using your product you have any problem and you wish to exchange or repair it, please do the following: 1) Obtain a Product Return Number (PRN) from our internet support at www.adfweb.com.