Flow Divider

The lift circuit for the front, outer lift cylinders includes a
flow divider. This flow divider provides for even lifting of
cutting units #4 and #5. The lift speed of #4 and #5 cut-
ting units should be similar when the flow divider is func-
tioning correctly. The flow divider assembly mounts to
the front carrier frame (Fig. 93).
The flow divider on early production machines consists
of a three (3) port manifold and a flow divider cartridge.
The flow divider on later production machines includes
a solenoid cartridge valve and two (2) flow regulator car-
tridges (Fig. 94).
If necessary, the cartridges can be carefully removed
from the manifold for cleaning.
Reelmaster 5500-D
8
4
9
10
1. Flow divider
2. O−ring
3. Hydraulic fitting
4. O−ring
5. Hydraulic hose
6. Cap screw (2 used)
30 to 35 ft−lb
(41 to 47 N−m)
1
1.
Manifold
2.
Solenoid cartridge valve
Page 4 - 85
5
4
6
7
2
3
2
1
2
8
4
11
Figure 93
7. Flat washer (2 used)
8. Hydraulic fitting
9. Hydraulic hose
10. Front carrier frame
11. Lock nut (2 used)
50 to 55 in−lb
(5.6 to 6.2 N−m)
4
2
20 to 25 ft−lb
(27 to 34 N−m)
3
Figure 94
3. Flow regulator cartridge
Hydraulic System (Rev. C)