11. Use an 8-32 machine screw to remove motor shaft
bearing retaining pin from housing (Fig. 47).
12.Remove motor shaft from housing (Fig. 48).
13.Press motor shaft out of the bearings and spacer
(Fig. 49).
14.Remove spiral retaining ring and remove PTO seal
guide (with O-ring) from the housing (Fig. 50).
Reelmaster 5500-D
Page 4 - 55
Figure 47
Figure 48
Figure 49
Figure 50
Hydraulic System (Rev. C)