6.14 TEMPERATURE READING SENSOR CONNECTION
The THERMOREGULATOR GLASS GLA810 activates the ventilation on the basis of the temperature of the output hot air
set.
The sensor must be positioned in the corrugated pipe supplying hot air
For the installation, follow the following steps (
1) Drill the tube;
2) Insert a washer on the sensor support and put it in the tube;
3) Screw the nut from the inner part of the tube in order to fix the sensor support to the tube;
4) Insert the sensor through the sensor-lock;
5) Screw the sensor-lock in the sensor holder so as to lock the sensor in its housing while holding the support.
6) Connect the sensor to the Thermoregulator (C) in pos. 9-10 (Fig. 6.15)
Fig. 6.14
Fig. 6.15
50
Fig. 6.14)
1
2
S1/S2
TERMOREGOLATORE GLASS GLA810 (Consultare manuale allegato)
THERMOREGULATOR GLASS GLA810 (Consult the manual annexed)
TEMPERATURREGLER GLASS GLA810 (Das Handbuch im Anhang konsultieren)
REGULATEUR DE TEMPERATURE GLASS GLA810 (consulter le manuel joint)
TERMORREGULADOR GLASS GLA810 (Consultar manual adjunto)
at 30 cm from the outlet of the chimney
:
1
LINEA
230 VAC
cod. 004777090 MBL - 19/12/2018 - Palazzetti - PN - Italy
S1
FUSE
12
11
10
9
S2
S1
T1,6 A
2
3
4
5
6
7
8
IN
VENT
SERV
SCI
230 VAC
.

Advertisement

Table of Contents