/ Lüfteranschlüsse / Connexions de ventilateurs / Conexiones de ventilador
6.12 FAN
6.12.1 FAN CONNECTIONS
The air environment fan (A) is located in the
lower part of the stove, and is provided with
series already connected to an extension
cable 3 meters long (B). (Fig. 6.12)
At the terminal side of the extension cable
there are three wires for connection to the
control unit (C) according to the attached
diagram.
The ground cable (T) must be connected to
the terminal (M) that connects the ground
cables from other applications (Fig. 6.11)
The cable of the phase of the fan must be
connected to the pos. 6 and the neutral wire
to the pos. 5 of the control unit (C).
6.12.2 FAN MALFUNCTION
• Check that power is going to the control unit;
• that the fuse is not blown;
• that the trigger temperature is 58°C
VENT
Fig. 6.12
46
Collegamenti ventilatore / Fan connections
CHANNEL AIR FLOW D=140 8M LINEAR CORRUGATED PIPE
Consumi elettrici-
Electricity consumption
Supply Voltage
Tensione di alimentazione-
Supply frequency
Frequenza di alimentazione-
TERMOREGOLATORE GLASS GLA810 (Consultare manuale allegato)
THERMOREGULATOR GLASS GLA810 (Consult the manual annexed)
TEMPERATURREGLER GLASS GLA810 (Das Handbuch im Anhang konsultieren)
REGULATEUR DE TEMPERATURE GLASS GLA810 (consulter le manuel joint)
TERMORREGULADOR GLASS GLA810 (Consultar manual adjunto)
M
T
N
L
cod. 004777090 MBL - 19/12/2018 - Palazzetti - PN - Italy
TOTAL FLOW 4 CHANNELS
FLOW SINGLE CHANNEL
FAN CAPACITY
W
52
V
230
Hz
50
FUSE
12
11
10
9
S2
S1
T1,6 A
1
2
3
4
5
6
7
8
IN
LINEA
VENT
SERV
SCI
230 VAC