6.5
SAFETY DISTANCES FROM FLAMMABLE
MATERIALS
• In presence of flammable structures or other materials
behind or besides the furnace, the minimum distance
from them must be as per the attached table. (FIG. 6.1)
• All flammable materials that are located in the area
in front of the door must be placed at a distance of at
least 180 cm from it.
6.6
EARTHING
ECOMONOBLOCCO WT 78 is provided with screw for
equipotential coupler that can receive a cable with cross-
section from 2.5 mm
the equipotential bonding of the earth in accordance with
the rules in force. This coupler is located in the rear part
of the ECOMONOBLOCCO WT 78 and indicated with
the symbol
(Fig. 6.2)
* For Italy these technicians must have the licence as per
letter "C" issued by the Chamber of Commerce according
to M.D. 37/08.
Also the flue system must be provided with its own earth
in accordance with local regulations.
FIG. 6.1
Y2
X1
cod. 004777090 MBL - 19/12/2018 - Palazzetti - PN - Italy
to 6 mm
, that can be used to obtain
2
2
[cm]
X1
180
X2
10
Y1
70
Y2
70
Z
Z