Figure 8: Articulating Mount (WS-MBO-ART01) for AP3965
1
Attach the small bracket on the WS-MBO-ART01 to the pole bracket with four M4 screws, verifying
that the AP orientation will be upright before you tighten the brackets screws. Torque the screws to
12 in-lbs.
2 Insert two cable/pipe clamps into the pole bracket. Attach the clamps to the pole where desired.
Torque the clamp screws to 12 in-lbs.
3 Attach the AP to the large bracket with four M4 screws. Torque the screws to 12.0 in-lbs.
4 If the AP needs to be tilted up or down, remove the screw
the AP to the desired angle. Re-insert the screw into the center hole in the black part of WS-MBO-
ART01. Torque the screw and nut to 12 in-lbs.
5 If the AP needs to be turned sideways, remove the screw
the AP to the desired angle. Re-insert the screw into the center hole in the black part of WS-MBO-
ART01. Torque the screw and nut to 12 in-lbs.
6 Remove the black gland cap and the gasket under it. Then separate the gasket from its plastic cage.
7 Attach the gland parts to the LAN cables and insert the LAN cables into the mating connectors in
the AP. For more information, see
8 Hand tighten the gland nuts and then tighten the nuts to a torque of 10 in-lbs.
9 Dress (adjust) the LAN and ground wires.
Mounting to a Solid Wall with an Articulated Bracket
To mount to a solid wall:
ExtremeWireless™ AP3965i & AP3965e Installation Guide
(see red arrows in previous
(see red arrows in previous
Attaching
Antennas.
Installation
figure) and tilt
figure) and tilt
19