Enter/Exit Programming Mode

Codabar Set Length 2

This feature specifies one of the barcode lengths for Codabar. Length 2 is the
maximum label length if in
length if in
start, stop, check and data characters. The length must include at least one
data character.
The length can be set from 3 to 50 characters. A setting of 0 specifies to ignore
this length (only one fixed length). For more detailed programming instructions
see, "Set Length" on
Table 14
Table 14. Codabar Length 2 Setting Examples
STEP
ACTION
Desired Setting (and pad
1
with leading zeroes)
2
Scan ENTER/EXIT PROGRAMMING MODE
3
Scan SELECT CODABAR LENGTH 2 SETTING
Scan Two Characters From
4
Appendix C
5
Scan ENTER/EXIT PROGRAMMING MODE
Select Codabar Length 2 Setting
Make a mistake? Scan the CANCEL barcode to abort and
not save the entry string. You can then start again at the
beginning.
134
Variable Length on page 93
Fixed Length on page 93
Chapter 4,
provides examples for setting Length 2.
EXAMPLES
00 Ignore This
Length
'0' and '0'
50 = Length 2 is 50 Characters
DEFAULT
Mode. The length includes the barcode's
References.
07 Characters
15 Characters
'0' and '7'
'1' and '5'
DSM0400 Fixed Mount Area Imager Bar Code Reader
Mode, or the second fixed
50 Characters
'5' AND '0'