Chapter 9
To Enable:
To Disable:
Name
seconds
9-34
ip irdp minadvertinterval
Command Mode: Interface
Description
Set the router discovery minimum time interval between IRDP
messages. The no form of this command restores the default value
of 0.75 times the maxadvertinterval.
Command Syntax
ip irdp minadvertinterval <seconds>
[no] ip irdp minadvertinterval
Table 9-21. Parameters, Keywords, Arguments
Definition
The minimum interval, in seconds, between
advertisements. The range is 3 - 1799
seconds.
Changing the maxadvertinterval value
defaults to the minadvertinterval value to
three-quarters of the new value.