ARP board
INPUT LEVEL control
This adjusts the input signal level to analog audio channels A1 and A2.
Adjustment range: –2 dB to +10 dB
OUTPUT LEVEL control
This adjusts the output signal level from analog audio channels A1 and A2.
Adjustment range: –10 dB to +2 dB
Playback signal monitor output switch
For playback signal monitoring, this switch determines the analog audio output
signal and the signal output to the headphones.
PWM: Plays back a signal PWM recorded on the analog audio tracks.
Use this setting when playing back a tape recorded on the PCM-3324S or PCM-
3348HR.
BIAS: Plays back a signal bias recorded on the analog audio tracks.
Use this setting when playing back a tape recorded on the PCM-3324A/3324.
COMPANDER switch
Switches on and off the compander function, compressing while recording the
analog audio signal and expanding during playback.
OFF: Disables the compander function. Use this setting when recording and
playing back signals other than audio signals.
NORM: Enables the compander function. Use this setting when recording and
playing back audio signals.
OUTPUT ADV/NORM (advance/normal) switch
When outputting an analog audio channel playback signal, this switch determines
whether or not to provide a delay.
ADV: Output the signal with no delay.
NORM: Output with a delay equal to the delay on the digital audio tracks.
PHONES LEVEL (headphones volume) control
Adjusts the volume of the headphones for monitoring analog audio channels A1 and A2.
PHONES (headphones) jack
Connect the headphones for monitoring analog audio channels A1 and A2.
SW501 switch
This switch is for factory adjustment only. Do not change the setting (NORM).