SDD ES ETH
Events of Safety Device Diagnostics
Number
0x300
0x301
0x302
0x303
0x304
0x305
0x306
0x320
Operating Manual SDD ES ETH
1003824-EN-06
Output text
Safety Gate!
Input
Input , Restart
Power ↑, please ↓
Power ↓, please ↑
Actuator
Actuator ♥
Lock
Meaning/action
The actuator has changed state
quickly.
}
Check and correct the misalign-
ment of switch and actuator and
correct if necessary.
Safety device in partially operated
status
}
Check the wiring.
Safety device in partial operation
lock status
}
Check the wiring and switch the
voltage off and then on again.
Supply voltage is at the upper limit
of the permitted range (see Tech-
nical details for safety device)
}
Ensure the supply voltage cor-
responds to the Technical de-
tails for the connected safety
device.
Supply voltage is at the lower limit
of the permitted range (see Tech-
nical details for safety device)
}
Ensure the supply voltage cor-
responds to the Technical de-
tails for the connected safety
device.
Wrong actuator signalled on
unique or fully coded versions of a
safety device
}
Use the actuator stated in the
operating manual for the safety
device.
New actuator has been taught in
}
Switch supply voltage off and
then on again.
Guard locking could not be activ-
ated or deactivated.
}
Check the wiring of the control
and the actuator.