Events Of Safety Device Diagnostics - Pilz SDD ES ETH Operating Manual

Table of Contents

Advertisement

SDD ES ETH

Events of Safety Device Diagnostics

Number
0x300
0x301
0x302
0x303
0x304
0x305
0x306
0x320
Operating Manual SDD ES ETH
1003824-EN-06
Output text
Safety Gate!
Input
Input , Restart
Power ↑, please ↓
Power ↓, please ↑
Actuator
Actuator ♥
Lock
Meaning/action
The actuator has changed state
quickly.
}
Check and correct the misalign-
ment of switch and actuator and
correct if necessary.
Safety device in partially operated
status
}
Check the wiring.
Safety device in partial operation
lock status
}
Check the wiring and switch the
voltage off and then on again.
Supply voltage is at the upper limit
of the permitted range (see Tech-
nical details for safety device)
}
Ensure the supply voltage cor-
responds to the Technical de-
tails for the connected safety
device.
Supply voltage is at the lower limit
of the permitted range (see Tech-
nical details for safety device)
}
Ensure the supply voltage cor-
responds to the Technical de-
tails for the connected safety
device.
Wrong actuator signalled on
unique or fully coded versions of a
safety device
}
Use the actuator stated in the
operating manual for the safety
device.
New actuator has been taught in
}
Switch supply voltage off and
then on again.
Guard locking could not be activ-
ated or deactivated.
}
Check the wiring of the control
and the actuator.