Pilz SDD ES ETH Operating Manual page 24

Table of Contents

Advertisement

SDD ES ETH
Device History
The last 23 messages since the SDD ES ETH was switched on are displayed.
The messages are described in the System Description "Safety Device Diagnostics".
Updated by reload: this page is updated by reloading the page in the browser.
Device Info
The information available about the connected safety devices on the SDD ES ETH is dis-
played.
Updated automatically: this page is updated automatically every second.
Column name
Device Info
Devices
Safety Gate
Lock
OSSD 1&2
I/O
Time in sec
Device Event
Display of events that have occurred. The last 23 entries are displayed.
The data is stored in a permanent memory and so is still available after the supply voltage
is switched back on.
The event number is displayed for each event, along with max. 3 additional lines with fur-
ther details. The events are described in detail in
diagnostics [
Updated by reload: this page is updated by reloading the page in the browser.
Device xx
Option
Coded Switch
Device Info
Operating Manual SDD ES ETH
1003824-EN-06
Value range
Meaning
Status of the SDD ES ETH
1-16
Number of connected safety devices
Green = closed
Status of the connected safety devices without
guard locking
Grey = open
Green = activ-
Status of the connected guard locking devices
ated
Grey = deactiv-
ated
Green = closed
Status of the connected OSSD
Grey = open
Value that is read in at the GPIOs
Time in seconds since power-up (jumps back to 0
after 65535 seconds)
28].
Value range
Meaning
e.g. Coded
Information about device type
Switch
/
Status of safety device (updated automatically)
Messages for safety device
Ready
Not available