SDD ES ETH
Number
0x321
0x900
0x901
0x902
0x903
0x904
0x905
0x906
0x907
0x908
Operating Manual SDD ES ETH
1003824-EN-06
Output text
Lock
**Start UP**
Chain
Please ↔ Device
Please Reset
OSSD 1&2
OSSD 1
OSSD 2
Power ↑, please ↓
Meaning/action
Guard locking is in a not defined
position.
}
Use the escape release to move
the guard locking into the open
state.
Switch the voltage off and then
on again
Fieldbus module and communica-
tion with the safety devices have
been restarted
Open circuit
}
Without stated safety device:
Connection from and to the field-
bus module has been interrup-
ted
}
With stated safety device: Con-
nection before the stated device
has been interrupted
Check the wiring and switch the
voltage off and then on again.
Internal error
}
Change the safety device.
Internal error
}
Check the wiring and switch the
voltage off and then on again.
Fault on the safety device output
}
Check the wiring and switch the
voltage off and then on again.
Fault on the safety device OSSD1
output
}
Check the wiring and switch the
voltage off and then on again.
Fault on the safety device OSSD2
output
}
Check the wiring and switch the
voltage off and then on again.
Supply voltage above the permit-
ted range (see Technical details
for safety device)
}
Reduce the supply voltage.
| 29