Using oval pipe to get past an obstruction
If a situation arises that obstructs the
CoolSmart flex vent runs (such as
getting past a minimum sideways
vent) you may transition the 5" flex
vent to a ridged nominal 6" oval pipe
to get past the obstruction. Transition
back to the 5" round flex and continue
to the manifold.
The adapters and ridged pipe should
be factory ovalized, not field ovalized.
NOTE: All clearances to combustibles
must be maintained.

CoolSmart TV - Reduced Mantel Height

When using this kit, disregard the combustible mantel requirements in the manual and follow the requirements
shown to the right. If you wish to place a TV above the mantel, it must meet the following requirements:
Minimum 1" air gap behind TV to wall.
The mantel must extend 2" (51mm) in front of the TV and 1" (26mm) to both sides.
47" (1194mm)
46" (1169mm)
45" (1143mm)
44" (1118mm)
43" (1093mm)
42" (1067mm)
41" (1042mm)
Mantel Height
40" (1016mm)
Above Base (a) With
39" (991mm)
CoolSmart TV Kit
38" (966mm)
37" (941mm)
36" (916mm)
35" (890mm)
34" (864mm)
© Travis Industries
Installation
(for qualified installers only)
5"
5"
5"
Maximum Mantel Depth (b) With
CoolSmart TV Kit
7-3/4"
3"
7-3/4"
3"
b
a
Min.
35"
ProBuilder 36
890mm
CF Fireplace
11/9/20 - 1503
61
5" Flex
to CoolSmart
Manifold
5" round to 6"
oval adapter
6" oval
pipe
5" round to 6"
oval adapter
5" Flex
to fireplace
Combustible Facing
(Min. 35" 890mm above
base of fireplace)
Non-Combustible
Facing Only
PB36 CF Install (Aust)