4
Install the LP pilot orifice following the instructions below.
(a) Use a 7/16" open-end wrench to remove the pilot hood.
(b) Remove and discard the Natural Gas (NG) orifice. Place the LP orifice in the pilot assembly then replace the pilot
hood, tightening the pilot hood until it is snug (do not over-tighten).
GSB2
© Travis Industries
Installation
(for qualified installers only)
a
7/16" Wrench
Natural Gas Orifice = .020N
LP (Propane) Orifce = .014LP
11/9/20 - 1503
b
.020N
or
.018N
.014LP
PB36 CF Install (Aust)