Remove the regulator from the front of the gas control valve. There is an knob extension on the regulator knob
that will need to be moved to the new regulator. To remove the extension pull toward you. Replace with the
propane regulator, using the new gasket and screws included with the regulator. Re-install the knob extension
onto the LP regulator knob. The knob extension is directional so you may need to turn it until it lines up properly
with the regulator knob and can be pushed into place..
NOTE: Leak test this area after the heater is installed, gas is connected, and the main burner is lit.
6
Make the gas line connection, bleed the gas line (if applicable), start the heater and thoroughly leak-test all gas
connections and the gas control valve.
© Travis Industries
Installation
(for qualified installers only)
Replace the regulator following the instructions included
with the regulator kit. Remove and discard the screws (see
"a" below) holding the stock regulator in place (see "b"
below). Remove the stock regulator and gasket (see "c"
below). Place the LP regulator in place, making sure the
pre-fitted gasket (see"c" below) is in place – make sure it
is correctly oriented. Secure using the screws included
with the motor – tighten to 25 Lb-inches. Leak test this
area after installation to verify proper installation.
There is a label on the base of the regulator knob indicating
regulator type (NG or LP). Place the included label on the
valve body where it can be easily seen to insure proper
identification ("d").