Lopi ProBuilder 36 CleanFace GSB2 Installation Manual page 52

Hide thumbs Also See for ProBuilder 36 CleanFace GSB2:
Table of Contents

Advertisement

52
Remove the 2 manifold covers and place them aside.
3
Follow the directions below to replace the orifice.
a
Slide the air shutters to provide access to the orifices.
b
Remove and discard the gaskets on each burner orifice.
Adjustable Wrench
Orifice
e
Screw each LP orifice until orifice
protrudes 15/16" (23.8mm)
indicating full insertion (use
wrench to support manifold when
re-attaching orifice).
© Travis Industries
Installation
(for qualified installers only)
Use a adjustable wrench to support the
c
manifold while removing each
orifice with a 1/2" wrench.
1/2" Open End Wrench
Manifold
11/9/20 - 1503
Apply thread sealant to the LP orifices
prior to installation. Use the chart below to
identify the correct orifices.
15/16"
Look here for the orifice identification
23.8mm
PB 36 Orifice Numbers
Front
Rear
d
NG
LP
#54
#63
#48
#57
PB36 CF Install (Aust)

Advertisement

Table of Contents
loading

Table of Contents